Dergi makalesi Açık Erişim
Asav, Engin; Sagiroglu, Ayten; Sezginturk, Mustafa Kemal
<?xml version='1.0' encoding='UTF-8'?> <record xmlns="http://www.loc.gov/MARC21/slim"> <leader>00000nam##2200000uu#4500</leader> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Sagiroglu, Ayten</subfield> <subfield code="u">Trakya Univ, Fac Sci, Dept Chem, TR-22030 Edirne, Turkey</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Sezginturk, Mustafa Kemal</subfield> <subfield code="u">Namik Kemal Univ, Fac Sci, Dept Chem, Tekirdag, Turkey</subfield> </datafield> <datafield tag="909" ind1="C" ind2="4"> <subfield code="p">ELECTROANALYSIS</subfield> <subfield code="v">28</subfield> <subfield code="n">2</subfield> <subfield code="c">334-342</subfield> </datafield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="540" ind1=" " ind2=" "> <subfield code="a">Creative Commons Attribution</subfield> <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield> </datafield> <datafield tag="024" ind1=" " ind2=" "> <subfield code="a">10.1002/elan.201500324</subfield> <subfield code="2">doi</subfield> </datafield> <datafield tag="245" ind1=" " ind2=" "> <subfield code="a">Quantitative Analysis of a Promising Cancer Biomarker, Calretinin, by a Biosensing System Based on Simple and Effective Immobilization Process</subfield> </datafield> <datafield tag="100" ind1=" " ind2=" "> <subfield code="a">Asav, Engin</subfield> <subfield code="u">Kirklareli Univ, Sch Hlth, TR-39000 Kirklareli, Turkey</subfield> </datafield> <datafield tag="909" ind1="C" ind2="O"> <subfield code="o">oai:zenodo.org:59215</subfield> <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="650" ind1="1" ind2="7"> <subfield code="2">opendefinition.org</subfield> <subfield code="a">cc-by</subfield> </datafield> <datafield tag="260" ind1=" " ind2=" "> <subfield code="c">2016-01-01</subfield> </datafield> <datafield tag="856" ind1="4" ind2=" "> <subfield code="u">https://aperta.ulakbim.gov.trrecord/59215/files/bib-da6acdb4-1c9b-459a-b93c-86cc2ed524b4.txt</subfield> <subfield code="z">md5:290c5d5b78747a23e953290266cb39a8</subfield> <subfield code="s">225</subfield> </datafield> <datafield tag="542" ind1=" " ind2=" "> <subfield code="l">open</subfield> </datafield> <controlfield tag="005">20210316004219.0</controlfield> <controlfield tag="001">59215</controlfield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">publication</subfield> <subfield code="b">article</subfield> </datafield> <datafield tag="520" ind1=" " ind2=" "> <subfield code="a">Calretinin (CAL) is calcium binding protein, and its levels in blood and cerebrospinal fluids are increased, since its expression is increased various cancer types. A novel biosensor system fabricated by immobilization of a specific antibody to CAL, anti-Calretinin (anti-CAL), onto a gold electrode surface via an effective covalent binding method using mercaptohexanol, epichlorohydrin, and ethanolamine was reported for the sensitive, selective, and accurate analysis of CAL. The proposed biosensor showed a linear calibration range between 1 ng/mL and 5 ng/mL. LOD and LOQ values were determined as 0.11 ng/mL and 0.38 ng/mL, respectively. The standard deviation related to the reproducibility of the new biosensor system was calculated as 3.95%. Lastly, in order to state the applicability of the biosensor to early diagnosis of CAL in practice, artificial serum samples spiked with CAL have been analyzed by the proposed biosensor.</subfield> </datafield> </record>
Görüntülenme | 23 |
İndirme | 6 |
Veri hacmi | 1.4 kB |
Tekil görüntülenme | 22 |
Tekil indirme | 6 |