Dergi makalesi Açık Erişim

Microbial Inactivation by Non-equilibrium Short-Pulsed Atmospheric Pressure Dielectric Barrier Discharge (Cold Plasma): Numerical and Experimental Studies

Arserim, Ender H.; Salvi, Deepti; Fridman, Gregory; Schaffner, Donald W.; Karwe, Mukund V.


Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Arserim, Ender H.</dc:creator>
  <dc:creator>Salvi, Deepti</dc:creator>
  <dc:creator>Fridman, Gregory</dc:creator>
  <dc:creator>Schaffner, Donald W.</dc:creator>
  <dc:creator>Karwe, Mukund V.</dc:creator>
  <dc:date>2020-01-01</dc:date>
  <dc:description>Microbial inactivation efficacy of plasma generated by a custom-made floating electrode dielectric barrier discharge (FE-DBD) or cold plasma at three different frequencies (1 kHz, 2 kHz, and 3.5 kHz) was experimentally evaluated for its inactivation of the pathogen surrogateEnterobacter aerogeneson a glass surface to obtain inactivation kinetics. COMSOL Multiphysics (R) was used to numerically simulate the amount and the distribution of reactive species within an FE-DBD system. Microbial inactivation kinetics was predicted using species concentrations and microbial inactivation rates from the literature and compared with experimental data. The results showed that the FE-DBD plasma treatment achieved a microbial reduction of 4.3 +/- 0.5 log CFU/surface at 3.5 kHz, 5.1 +/- 0.09 log CFU/surface at 2 kHz, and 5.1 +/- 0.05 log CFU/surface at 1 kHz in 2 min, 3 min, and 6 min, respectively. The predicted values were 4.02 log CFU/surface, 4.10 log CFU/surface, and 4.56 log CFU/surface at 1 kHz, 2 kHz, and 3.5 kHz, respectively. A maximum 1 log difference was observed between numerical predictions and the experimental results. The difference might be due to synergistic interactions between plasma species, UV component of FE-DBD plasma, and/or the electrical field effects, which could not be included in the numerical simulation.</dc:description>
  <dc:identifier>https://aperta.ulakbim.gov.trrecord/9597</dc:identifier>
  <dc:identifier>oai:zenodo.org:9597</dc:identifier>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights>
  <dc:source>FOOD ENGINEERING REVIEWS</dc:source>
  <dc:title>Microbial Inactivation by Non-equilibrium Short-Pulsed Atmospheric Pressure Dielectric Barrier Discharge (Cold Plasma): Numerical and Experimental Studies</dc:title>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:type>publication-article</dc:type>
</oai_dc:dc>
32
7
görüntülenme
indirilme
Görüntülenme 32
İndirme 7
Veri hacmi 1.8 kB
Tekil görüntülenme 31
Tekil indirme 7

Alıntı yap