Dergi makalesi Açık Erişim

Resolving tissue chromophore concentration at MRI resolution using multi-wavelength photo-magnetic imaging

Algarawi, Maha; Erkol, Hakan; Luk, Alex; Ha, Seunghoon; Unlu, Mehmet B.; Gulsen, Gultekin; Nouizi, Farouk


JSON

{
  "conceptrecid": "5148", 
  "created": "2021-03-15T06:08:02.549635+00:00", 
  "doi": "10.1364/BOE.397538", 
  "files": [
    {
      "bucket": "fb8e14b8-2f3d-48c0-a344-678e7af1a97a", 
      "checksum": "md5:5f177578a3a96bb097cb16da5fd3c309", 
      "key": "bib-1b0ccea2-a7a3-4ed3-a6bb-3fc01ac859fc.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/fb8e14b8-2f3d-48c0-a344-678e7af1a97a/bib-1b0ccea2-a7a3-4ed3-a6bb-3fc01ac859fc.txt"
      }, 
      "size": 236, 
      "type": "txt"
    }
  ], 
  "id": 5149, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1364/BOE.397538.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/fb8e14b8-2f3d-48c0-a344-678e7af1a97a", 
    "doi": "https://doi.org/10.1364/BOE.397538", 
    "html": "https://aperta.ulakbim.gov.tr/record/5149", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/5149", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/5149"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-destekli-proje-yayinlari"
      }
    ], 
    "creators": [
      {
        "name": "Algarawi, Maha"
      }, 
      {
        "affiliation": "Bogazici Univ, Dept Phys, Istanbul, Turkey", 
        "name": "Erkol, Hakan"
      }, 
      {
        "affiliation": "Univ Calif Irvine, Ctr Funct Oncoimaging, Irvine, CA 92697 USA", 
        "name": "Luk, Alex"
      }, 
      {
        "affiliation": "Philips Healthcare, Pewaukee, WI 53002 USA", 
        "name": "Ha, Seunghoon"
      }, 
      {
        "affiliation": "Bogazici Univ, Dept Phys, Istanbul, Turkey", 
        "name": "Unlu, Mehmet B."
      }, 
      {
        "name": "Gulsen, Gultekin"
      }, 
      {
        "name": "Nouizi, Farouk"
      }
    ], 
    "description": "Photo-magnetic imaging (PMI) is an emerging optical imaging modality that showed great performance on providing absorption maps with high resolution and quantitative accuracy. As a multi-modality technology, PMI warms up the imaged object using a near infrared laser while temperature variation is measured using magnetic resonance imaging. By probing tissue at multiple wavelengths, concentration of the main tissue chromophores such as oxy-and deoxy-hemoglobin, lipid, and water are obtained then used to derive functional parameters such as total hemoglobin concentration and relative oxygen saturation. In this paper, we present a multi-wavelength PMI system that was custom-built to host five different laser wavelengths. After recovering the high-resolution absorption maps, a least-squared minimization process was used to resolve the different chromophore concentration. The performance of the system was experimentally tested on a phantom with two different dyes. Their concentrations were successfully assessed with high spatial resolution and average accuracy of nearly 80%. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement", 
    "doi": "10.1364/BOE.397538", 
    "has_grant": false, 
    "journal": {
      "issue": "8", 
      "pages": "4244-4254", 
      "title": "BIOMEDICAL OPTICS EXPRESS", 
      "volume": "11"
    }, 
    "license": {
      "id": "cc-by"
    }, 
    "publication_date": "2020-01-01", 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "5149"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "5148"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "article", 
      "title": "Dergi makalesi", 
      "type": "publication"
    }, 
    "title": "Resolving tissue chromophore concentration at MRI resolution using multi-wavelength photo-magnetic imaging"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 5.0, 
    "unique_downloads": 5.0, 
    "unique_views": 35.0, 
    "version_downloads": 5.0, 
    "version_unique_downloads": 5.0, 
    "version_unique_views": 35.0, 
    "version_views": 38.0, 
    "version_volume": 1180.0, 
    "views": 38.0, 
    "volume": 1180.0
  }, 
  "updated": "2021-03-15T06:08:02.589033+00:00"
}
38
5
görüntülenme
indirilme
Görüntülenme 38
İndirme 5
Veri hacmi 1.2 kB
Tekil görüntülenme 35
Tekil indirme 5

Alıntı yap