Dergi makalesi Açık Erişim
Armutcu, Canan; Uzun, Lokman; Denizli, Adil
{ "conceptrecid": "33060", "created": "2021-03-15T18:50:36.648844+00:00", "doi": "10.1016/j.chroma.2018.07.057", "files": [ { "bucket": "3fd4570f-8925-4d09-8595-47b13afeab5b", "checksum": "md5:1e9417b9ce2fce0f34ba44cc64c6591d", "key": "bib-8f146e7a-3e3b-47d6-aea0-38a2205cb706.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/3fd4570f-8925-4d09-8595-47b13afeab5b/bib-8f146e7a-3e3b-47d6-aea0-38a2205cb706.txt" }, "size": 310, "type": "txt" } ], "id": 33061, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1016/j.chroma.2018.07.057.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/3fd4570f-8925-4d09-8595-47b13afeab5b", "doi": "https://doi.org/10.1016/j.chroma.2018.07.057", "html": "https://aperta.ulakbim.gov.tr/record/33061", "latest": "https://aperta.ulakbim.gov.tr/api/records/33061", "latest_html": "https://aperta.ulakbim.gov.tr/record/33061" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-destekli-proje-yayinlari" } ], "creators": [ { "affiliation": "Hacettepe Univ, Dept Chem, Ankara, Turkey", "name": "Armutcu, Canan" }, { "affiliation": "Hacettepe Univ, Dept Chem, Ankara, Turkey", "name": "Uzun, Lokman" }, { "affiliation": "Hacettepe Univ, Dept Chem, Ankara, Turkey", "name": "Denizli, Adil" } ], "description": "Automated on-line two-dimensional high-performance liquid chromatography method (2D-HPLC) is proposed to determine Ochratoxin A (OTA) in food samples as an alternative to OTA immunoaffinity column (IAC). An on-line 2D-HPLC system is designed for the analysis of OTA using an affinity-based monolithic column in the first dimension and reversed-phase C18 column in the second dimension. Initially, optimal OTA separation efficiency is determined through traditional HPLC system consisting of a P(HEMAPA) monolithic column coupled with HPLC system. Secondly, after providing optimum conditions, OTA determination was investigated through the 2D-HPLC system. According to results, 2D-HPLC system showed good linearity in the range 0.5 to 20 ng/mL with limit of detection (LOD) and limit of quantification (LOQ) values of 21.2 pg/mL and 64.3 pg/mL, respectively. The P(HEMAPA)-4 monolithic column displayed good recovery of OTA ranging from 104.34% to 107.33%. Relative standard deviations (RSD) varied in the range 0.21% to 1.31% thus indicating the efficiency of P(HEMAPA)-4 monolithic column developed for OTA. (C) 2018 Elsevier B.V. All rights reserved.", "doi": "10.1016/j.chroma.2018.07.057", "has_grant": false, "journal": { "pages": "139-148", "title": "JOURNAL OF CHROMATOGRAPHY A", "volume": "1569" }, "license": { "id": "cc-by" }, "publication_date": "2018-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "33061" }, "parent": { "pid_type": "recid", "pid_value": "33060" } } ] }, "resource_type": { "subtype": "article", "title": "Dergi makalesi", "type": "publication" }, "title": "Determination of Ochratoxin A traces in foodstuffs: Comparison of an automated on-line two-dimensional high-performance liquid chromatography and off-line immunoaffinity-high-performance liquid chromatography system" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 3.0, "unique_downloads": 3.0, "unique_views": 13.0, "version_downloads": 3.0, "version_unique_downloads": 3.0, "version_unique_views": 13.0, "version_views": 13.0, "version_volume": 930.0, "views": 13.0, "volume": 930.0 }, "updated": "2021-03-15T18:50:36.696821+00:00" }
Görüntülenme | 13 |
İndirme | 3 |
Veri hacmi | 930 Bytes |
Tekil görüntülenme | 13 |
Tekil indirme | 3 |