{ "@context": "https://schema.org/", "@id": 97279, "@type": "ScholarlyArticle", "creator": [ { "@type": "Person", "name": "Kaya, Durmus" }, { "@type": "Person", "name": "Sarac, H. Ibrahim" } ], "datePublished": "2007-01-01", "description": "In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on evaporation process was investigated from the point of energy economy. A sugar factory's data was used with the applied models as a case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating. (c) 2006 Elsevier Ltd. All rights reserved.", "headline": "Mathematical modeling of multiple-effect evaporators and energy economy", "identifier": 97279, "image": "https://aperta.ulakbim.gov.tr/static/img/logo/aperta_logo_with_icon.svg", "license": "http://www.opendefinition.org/licenses/cc-by", "name": "Mathematical modeling of multiple-effect evaporators and energy economy", "url": "https://aperta.ulakbim.gov.tr/record/97279" }