Dergi makalesi Açık Erişim
Kaya, Durmus; Sarac, H. Ibrahim
{
"DOI": "10.1016/j.energy.2006.09.002",
"abstract": "In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on evaporation process was investigated from the point of energy economy. A sugar factory's data was used with the applied models as a case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating. (c) 2006 Elsevier Ltd. All rights reserved.",
"author": [
{
"family": "Kaya",
"given": " Durmus"
},
{
"family": "Sarac",
"given": " H. Ibrahim"
}
],
"container_title": "ENERGY",
"id": "97279",
"issue": "8",
"issued": {
"date-parts": [
[
2007,
1,
1
]
]
},
"page": "1536-1542",
"title": "Mathematical modeling of multiple-effect evaporators and energy economy",
"type": "article-journal",
"volume": "32"
}
| Görüntülenme | 88 |
| İndirme | 11 |
| Veri hacmi | 1.4 kB |
| Tekil görüntülenme | 83 |
| Tekil indirme | 11 |