Dergi makalesi Açık Erişim

Mathematical modeling of multiple-effect evaporators and energy economy

Kaya, Durmus; Sarac, H. Ibrahim


JSON

{
  "conceptrecid": "97278", 
  "created": "2021-03-16T13:41:30.984342+00:00", 
  "doi": "10.1016/j.energy.2006.09.002", 
  "files": [
    {
      "bucket": "53f6a569-337c-4858-8ad0-f1ab71b3a177", 
      "checksum": "md5:e5b3044b02f531db5b6db15d5586d914", 
      "key": "bib-157d3720-6030-421b-8ba0-1fe8f424c155.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/53f6a569-337c-4858-8ad0-f1ab71b3a177/bib-157d3720-6030-421b-8ba0-1fe8f424c155.txt"
      }, 
      "size": 127, 
      "type": "txt"
    }
  ], 
  "id": 97279, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1016/j.energy.2006.09.002.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/53f6a569-337c-4858-8ad0-f1ab71b3a177", 
    "doi": "https://doi.org/10.1016/j.energy.2006.09.002", 
    "html": "https://aperta.ulakbim.gov.tr/record/97279", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/97279", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/97279"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-adresli-yayinlar"
      }
    ], 
    "creators": [
      {
        "name": "Kaya, Durmus"
      }, 
      {
        "name": "Sarac, H. Ibrahim"
      }
    ], 
    "description": "In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on evaporation process was investigated from the point of energy economy. A sugar factory's data was used with the applied models as a case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating. (c) 2006 Elsevier Ltd. All rights reserved.", 
    "doi": "10.1016/j.energy.2006.09.002", 
    "has_grant": false, 
    "journal": {
      "issue": "8", 
      "pages": "1536-1542", 
      "title": "ENERGY", 
      "volume": "32"
    }, 
    "license": {
      "id": "cc-by"
    }, 
    "publication_date": "2007-01-01", 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "97279"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "97278"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "article", 
      "title": "Dergi makalesi", 
      "type": "publication"
    }, 
    "title": "Mathematical modeling of multiple-effect evaporators and energy economy"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 5.0, 
    "unique_downloads": 5.0, 
    "unique_views": 50.0, 
    "version_downloads": 5.0, 
    "version_unique_downloads": 5.0, 
    "version_unique_views": 50.0, 
    "version_views": 50.0, 
    "version_volume": 635.0, 
    "views": 50.0, 
    "volume": 635.0
  }, 
  "updated": "2021-03-16T13:41:31.037815+00:00"
}
50
5
görüntülenme
indirilme
Görüntülenme 50
İndirme 5
Veri hacmi 635 Bytes
Tekil görüntülenme 50
Tekil indirme 5

Alıntı yap