Dergi makalesi Açık Erişim
Kaya, Durmus; Sarac, H. Ibrahim
In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on evaporation process was investigated from the point of energy economy. A sugar factory's data was used with the applied models as a case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating. (c) 2006 Elsevier Ltd. All rights reserved.
Dosya adı | Boyutu | |
---|---|---|
bib-157d3720-6030-421b-8ba0-1fe8f424c155.txt
md5:e5b3044b02f531db5b6db15d5586d914 |
127 Bytes | İndir |
Görüntülenme | 88 |
İndirme | 11 |
Veri hacmi | 1.4 kB |
Tekil görüntülenme | 83 |
Tekil indirme | 11 |
Kaya, D. ve Sarac, H. I. (2007). Mathematical modeling of multiple-effect evaporators and energy economy. ENERGY, 32(8), 1536–1542. doi:10.1016/j.energy.2006.09.002