Dergi makalesi Açık Erişim
Goren, AC; Bilsel, G; Bilsel, M; Yenisoy-Karakas, S; Karakas, D
<?xml version='1.0' encoding='UTF-8'?> <record xmlns="http://www.loc.gov/MARC21/slim"> <leader>00000nam##2200000uu#4500</leader> <datafield tag="540" ind1=" " ind2=" "> <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield> <subfield code="a">Creative Commons Attribution</subfield> </datafield> <datafield tag="909" ind1="C" ind2="O"> <subfield code="o">oai:zenodo.org:94623</subfield> <subfield code="p">user-tubitak-adresli-yayinlar</subfield> </datafield> <datafield tag="520" ind1=" " ind2=" "> <subfield code="a">Atropine and obidoxime in a parenteral injection device are determined by simple HPLC method simultaneously without any pretreatment at 228 nm. The relative standard deviations (R.S.D.) were below 1.6% for the compounds. The correlation coefficient was greater than 0.999 for both compounds in the calibration range. The recoveries at 5 mg/L concentration averaged as 95% for atropine and 102% for obidoxime. The uncertainty of the measurements for atropine and obidoxime was 2.8% and 2.4%, respectively. (C) 2004 Elsevier B.V. All rights reserved.</subfield> </datafield> <datafield tag="650" ind1="1" ind2="7"> <subfield code="a">cc-by</subfield> <subfield code="2">opendefinition.org</subfield> </datafield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">user-tubitak-adresli-yayinlar</subfield> </datafield> <datafield tag="909" ind1="C" ind2="4"> <subfield code="n">1-2</subfield> <subfield code="v">1057</subfield> <subfield code="c">237-239</subfield> <subfield code="p">JOURNAL OF CHROMATOGRAPHY A</subfield> </datafield> <datafield tag="260" ind1=" " ind2=" "> <subfield code="c">2004-01-01</subfield> </datafield> <datafield tag="024" ind1=" " ind2=" "> <subfield code="a">10.1016/j.chroma.2004.09.048</subfield> <subfield code="2">doi</subfield> </datafield> <controlfield tag="001">94623</controlfield> <datafield tag="100" ind1=" " ind2=" "> <subfield code="a">Goren, AC</subfield> </datafield> <datafield tag="856" ind1="4" ind2=" "> <subfield code="u">https://aperta.ulakbim.gov.trrecord/94623/files/bib-76df0da4-7eab-4bfb-a7fb-f7f792d39b57.txt</subfield> <subfield code="s">257</subfield> <subfield code="z">md5:616fc564bccb1a52b3e75e06af2d040c</subfield> </datafield> <controlfield tag="005">20210316130444.0</controlfield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">publication</subfield> <subfield code="b">article</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Bilsel, G</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Bilsel, M</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Yenisoy-Karakas, S</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Karakas, D</subfield> </datafield> <datafield tag="245" ind1=" " ind2=" "> <subfield code="a">Simple high-performance liquid chromatographic method for determination of atropine and obidoxime in a parenteral injection device</subfield> </datafield> <datafield tag="542" ind1=" " ind2=" "> <subfield code="l">open</subfield> </datafield> </record>
Görüntülenme | 10 |
İndirme | 4 |
Veri hacmi | 1.0 kB |
Tekil görüntülenme | 10 |
Tekil indirme | 4 |