Dergi makalesi Açık Erişim

Simple high-performance liquid chromatographic method for determination of atropine and obidoxime in a parenteral injection device

Goren, AC; Bilsel, G; Bilsel, M; Yenisoy-Karakas, S; Karakas, D


JSON

{
  "conceptrecid": "94622", 
  "created": "2021-03-16T13:04:44.200816+00:00", 
  "doi": "10.1016/j.chroma.2004.09.048", 
  "files": [
    {
      "bucket": "dc46a300-7e2d-4d2f-9893-37e7f4e54067", 
      "checksum": "md5:616fc564bccb1a52b3e75e06af2d040c", 
      "key": "bib-76df0da4-7eab-4bfb-a7fb-f7f792d39b57.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/dc46a300-7e2d-4d2f-9893-37e7f4e54067/bib-76df0da4-7eab-4bfb-a7fb-f7f792d39b57.txt"
      }, 
      "size": 257, 
      "type": "txt"
    }
  ], 
  "id": 94623, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1016/j.chroma.2004.09.048.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/dc46a300-7e2d-4d2f-9893-37e7f4e54067", 
    "doi": "https://doi.org/10.1016/j.chroma.2004.09.048", 
    "html": "https://aperta.ulakbim.gov.tr/record/94623", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/94623", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/94623"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-adresli-yayinlar"
      }
    ], 
    "creators": [
      {
        "name": "Goren, AC"
      }, 
      {
        "name": "Bilsel, G"
      }, 
      {
        "name": "Bilsel, M"
      }, 
      {
        "name": "Yenisoy-Karakas, S"
      }, 
      {
        "name": "Karakas, D"
      }
    ], 
    "description": "Atropine and obidoxime in a parenteral injection device are determined by simple HPLC method simultaneously without any pretreatment at 228 nm. The relative standard deviations (R.S.D.) were below 1.6% for the compounds. The correlation coefficient was greater than 0.999 for both compounds in the calibration range. The recoveries at 5 mg/L concentration averaged as 95% for atropine and 102% for obidoxime. The uncertainty of the measurements for atropine and obidoxime was 2.8% and 2.4%, respectively. (C) 2004 Elsevier B.V. All rights reserved.", 
    "doi": "10.1016/j.chroma.2004.09.048", 
    "has_grant": false, 
    "journal": {
      "issue": "1-2", 
      "pages": "237-239", 
      "title": "JOURNAL OF CHROMATOGRAPHY A", 
      "volume": "1057"
    }, 
    "license": {
      "id": "cc-by"
    }, 
    "publication_date": "2004-01-01", 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "94623"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "94622"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "article", 
      "title": "Dergi makalesi", 
      "type": "publication"
    }, 
    "title": "Simple high-performance liquid chromatographic method for determination of atropine and obidoxime in a parenteral injection device"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 4.0, 
    "unique_downloads": 4.0, 
    "unique_views": 10.0, 
    "version_downloads": 4.0, 
    "version_unique_downloads": 4.0, 
    "version_unique_views": 10.0, 
    "version_views": 10.0, 
    "version_volume": 1028.0, 
    "views": 10.0, 
    "volume": 1028.0
  }, 
  "updated": "2021-03-16T13:04:44.249249+00:00"
}
10
4
görüntülenme
indirilme
Görüntülenme 10
İndirme 4
Veri hacmi 1.0 kB
Tekil görüntülenme 10
Tekil indirme 4

Alıntı yap