Dergi makalesi Açık Erişim

Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography

Armutcu, Canan; Ozgur, Erdogan; Karasu, Tunca; Bayram, Engin; Uzun, Lokman; Corman, Mehmet Emin


Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Armutcu, Canan</dc:creator>
  <dc:creator>Ozgur, Erdogan</dc:creator>
  <dc:creator>Karasu, Tunca</dc:creator>
  <dc:creator>Bayram, Engin</dc:creator>
  <dc:creator>Uzun, Lokman</dc:creator>
  <dc:creator>Corman, Mehmet Emin</dc:creator>
  <dc:date>2019-01-01</dc:date>
  <dc:description>Two-dimensional HPLC (2D-HPLC) recently has received great attention due to providing high resolving power and higher peak capacities than that of 1D-HPLC, especially dealing with a wide spectrum of sample matrices containing several components. In this work, an on-line heart-cutting two-dimensional liquid chromatography (2D-LC) method was developed using monolithic columns coupled with reversed-phase liquid chromatography (RPLC). 2D-HPLC was successfully carried out using affinity-based monolithic columns at first dimension (20 cm x 4.6 mm I.D.) followed by a Pinnacle II PAH column (50 mm x 4.6 mm I.D.) at the second dimension. Furthermore, good linearity was observed for the correlation of the benzo[a]pyrene (BaP) molecule against the peak areas (R-2 = 0.994) in the concentration range of 0.01-1.0 ng/mL in 30 min. The limit of detection and the limit of quantification were found to be 4.0 pg/mL and 12.0 pg/mL, respectively. Both the intra-day and inter-day precision at 0.01 and 0.1 ng/mL spiked concentrations were below than 2.35% RSD whereas the means of the recovery data of the BaP from the water samples were found to be in the range of 93.71-98.65%. These results demonstrate that the 2D-HPLC system, developed by the combination of the P(HEMA-MAPA) column and Pinnacle II PAH column, is reliable, stable, and well qualified in the extraction of polycyclic aromatic hydrocarbons from the water samples.</dc:description>
  <dc:identifier>https://aperta.ulakbim.gov.trrecord/67469</dc:identifier>
  <dc:identifier>oai:zenodo.org:67469</dc:identifier>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights>
  <dc:source>WATER AIR AND SOIL POLLUTION 230(10)</dc:source>
  <dc:title>Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography</dc:title>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:type>publication-article</dc:type>
</oai_dc:dc>
24
6
görüntülenme
indirilme
Görüntülenme 24
İndirme 6
Veri hacmi 1.5 kB
Tekil görüntülenme 22
Tekil indirme 6

Alıntı yap