Dergi makalesi Açık Erişim

Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography

Armutcu, Canan; Ozgur, Erdogan; Karasu, Tunca; Bayram, Engin; Uzun, Lokman; Corman, Mehmet Emin


JSON-LD (schema.org)

{
  "@context": "https://schema.org/", 
  "@id": 67469, 
  "@type": "ScholarlyArticle", 
  "creator": [
    {
      "@type": "Person", 
      "affiliation": "Hacettepe Univ, Dept Chem, Fac Sci, Ankara, Turkey", 
      "name": "Armutcu, Canan"
    }, 
    {
      "@type": "Person", 
      "name": "Ozgur, Erdogan"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Sinop Univ, Dept Chem, Fac Sci & Arts, Sinop, Turkey", 
      "name": "Karasu, Tunca"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Hacettepe Univ, Dept Chem, Fac Sci, Ankara, Turkey", 
      "name": "Bayram, Engin"
    }, 
    {
      "@type": "Person", 
      "name": "Uzun, Lokman"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Sinop Univ, Dept Chem, Fac Sci & Arts, Sinop, Turkey", 
      "name": "Corman, Mehmet Emin"
    }
  ], 
  "datePublished": "2019-01-01", 
  "description": "Two-dimensional HPLC (2D-HPLC) recently has received great attention due to providing high resolving power and higher peak capacities than that of 1D-HPLC, especially dealing with a wide spectrum of sample matrices containing several components. In this work, an on-line heart-cutting two-dimensional liquid chromatography (2D-LC) method was developed using monolithic columns coupled with reversed-phase liquid chromatography (RPLC). 2D-HPLC was successfully carried out using affinity-based monolithic columns at first dimension (20 cm x 4.6 mm I.D.) followed by a Pinnacle II PAH column (50 mm x 4.6 mm I.D.) at the second dimension. Furthermore, good linearity was observed for the correlation of the benzo[a]pyrene (BaP) molecule against the peak areas (R-2 = 0.994) in the concentration range of 0.01-1.0 ng/mL in 30 min. The limit of detection and the limit of quantification were found to be 4.0 pg/mL and 12.0 pg/mL, respectively. Both the intra-day and inter-day precision at 0.01 and 0.1 ng/mL spiked concentrations were below than 2.35% RSD whereas the means of the recovery data of the BaP from the water samples were found to be in the range of 93.71-98.65%. These results demonstrate that the 2D-HPLC system, developed by the combination of the P(HEMA-MAPA) column and Pinnacle II PAH column, is reliable, stable, and well qualified in the extraction of polycyclic aromatic hydrocarbons from the water samples.", 
  "headline": "Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography", 
  "identifier": 67469, 
  "image": "https://aperta.ulakbim.gov.tr/static/img/logo/aperta_logo_with_icon.svg", 
  "license": "http://www.opendefinition.org/licenses/cc-by", 
  "name": "Rapid Analysis of Polycyclic Aromatic Hydrocarbons in Water Samples Using an Automated On-line Two-Dimensional Liquid Chromatography", 
  "url": "https://aperta.ulakbim.gov.tr/record/67469"
}
37
6
görüntülenme
indirilme
Görüntülenme 37
İndirme 6
Veri hacmi 1.5 kB
Tekil görüntülenme 32
Tekil indirme 6

Alıntı yap