Dergi makalesi Açık Erişim
Kublay, Irem Zehra; Kocoglu, Elif Seda; Oflu, Sude; Arvas, Busra; Yolacan, Cigdem; Bakirdere, Sezgin
<?xml version='1.0' encoding='UTF-8'?> <record xmlns="http://www.loc.gov/MARC21/slim"> <leader>00000nam##2200000uu#4500</leader> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Kocoglu, Elif Seda</subfield> <subfield code="u">Yildiz Tech Univ, Cent Res Lab, TR-34220 Istanbul, Turkiye</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Oflu, Sude</subfield> <subfield code="u">Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34220 Istanbul, Turkiye</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Arvas, Busra</subfield> <subfield code="u">Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34220 Istanbul, Turkiye</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Yolacan, Cigdem</subfield> <subfield code="u">Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34220 Istanbul, Turkiye</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Bakirdere, Sezgin</subfield> </datafield> <datafield tag="909" ind1="C" ind2="4"> <subfield code="p">ENVIRONMENTAL MONITORING AND ASSESSMENT</subfield> <subfield code="v">195</subfield> <subfield code="n">7</subfield> <subfield code="c">10</subfield> </datafield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="540" ind1=" " ind2=" "> <subfield code="a">Creative Commons Attribution</subfield> <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield> </datafield> <datafield tag="024" ind1=" " ind2=" "> <subfield code="a">10.1007/s10661-023-11435-y</subfield> <subfield code="2">doi</subfield> </datafield> <datafield tag="245" ind1=" " ind2=" "> <subfield code="a">Trace nickel determination in seawater matrix using combination of dispersive liquid-liquid microextraction and triethylamine-assisted Mg(OH)<sub>2</sub> method</subfield> </datafield> <datafield tag="100" ind1=" " ind2=" "> <subfield code="a">Kublay, Irem Zehra</subfield> <subfield code="u">Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34220 Istanbul, Turkiye</subfield> </datafield> <datafield tag="909" ind1="C" ind2="O"> <subfield code="o">oai:aperta.ulakbim.gov.tr:269168</subfield> <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield> </datafield> <datafield tag="650" ind1="1" ind2="7"> <subfield code="2">opendefinition.org</subfield> <subfield code="a">cc-by</subfield> </datafield> <datafield tag="260" ind1=" " ind2=" "> <subfield code="c">2023-01-01</subfield> </datafield> <datafield tag="856" ind1="4" ind2=" "> <subfield code="u">https://aperta.ulakbim.gov.trrecord/269168/files/bib-9214b303-8cab-4195-9301-03e8317cafcb.txt</subfield> <subfield code="z">md5:811fce3c8b4706cf1c2fd10cc9243faf</subfield> <subfield code="s">304</subfield> </datafield> <datafield tag="542" ind1=" " ind2=" "> <subfield code="l">open</subfield> </datafield> <controlfield tag="005">20240607134442.0</controlfield> <controlfield tag="001">269168</controlfield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">publication</subfield> <subfield code="b">article</subfield> </datafield> <datafield tag="520" ind1=" " ind2=" "> <subfield code="a"><p>In order to eliminate the effects of seawater matrix on the precise/accurate determination of elements, new and efficient analytical procedure requires. In this study, co-precipitation method based on the triethylamine (TEA)-assisted Mg(OH)(2) was performed to eliminate side-effects of seawater medium on the determination with flame atomic absorption spectrometry (FAAS) prior to the preconcentration of nickel by an optimized dispersive liquid-liquid microextraction (DLLME) method. Under the optimum conditions of the presented method, the limit of detection and quantification (LOD, LOQ) values obtained for nickel were found as 16.1 and 53.8 &amp; mu;g kg(-1), respectively. Seawater samples collected from West Antarctic region were used for real sample applications to check the accuracy and applicability of developed method, and satisfying recovery results (86-97%) were obtained. In addition to this, the digital image-based colorimetric detection system and the UV-Vis system were applied to confirm the applicability of the developed DLLME-FAAS method in other analytical systems.</p></subfield> </datafield> </record>
Görüntülenme | 0 |
İndirme | 0 |
Veri hacmi | 0 Bytes |
Tekil görüntülenme | 0 |
Tekil indirme | 0 |