Dergi makalesi Açık Erişim

Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection

Kalkan, Zeycan; Yence, Merve; Turk, Fatih; Bektas, Tamer U.; Ozturk, Soner; Surdem, Sedat; Yildirim-Tirgil, Nimet


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Yence, Merve</subfield>
    <subfield code="u">Boron Res Inst, TENMAK, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Turk, Fatih</subfield>
    <subfield code="u">Ankara Yildirim Beyazit Univ, Fac Engn &amp; Nat Sci, Mat Engn, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Bektas, Tamer U.</subfield>
    <subfield code="u">Ankara Yildirim Beyazit Univ, Fac Engn &amp; Nat Sci, Mat Engn, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Ozturk, Soner</subfield>
    <subfield code="u">Boron Res Inst, TENMAK, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Surdem, Sedat</subfield>
    <subfield code="u">Boron Res Inst, TENMAK, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Yildirim-Tirgil, Nimet</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">ELECTROANALYSIS</subfield>
    <subfield code="v">34</subfield>
    <subfield code="n">1</subfield>
    <subfield code="c">33-42</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1002/elan.202100271</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Kalkan, Zeycan</subfield>
    <subfield code="u">Ankara Yildirim Beyazit Univ, Fac Engn &amp; Nat Sci, Mat Engn, Ankara, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:aperta.ulakbim.gov.tr:232646</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2022-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/232646/files/bib-e7242b59-3fd9-4ad8-a533-f08841d66346.txt</subfield>
    <subfield code="z">md5:8534be2febbbe18e40e0b5bc0b27f1f9</subfield>
    <subfield code="s">222</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20221007082811.0</controlfield>
  <controlfield tag="001">232646</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">In this research, an electrochemical enzymatic biosensor system for sensitive and selective catechol detection was developed with using boric acid substituted Polyaniline film coated two different electrodes; gold screen-printed electrode and glassy carbon electrode. Electropolymerization of 3-aminophenylboronic acid is carried out through various electropolymerization conditions, and the best conditions for biosensors systems are concluded. The developed tyrosinase enzyme-based biosensor system is used for the determination of catechol. The limit of detections(LOD) of the developed biosensor was 0.25 mu M and 1.8 mu M with Au SPE and GCE systems, respectively. Additionally, real sample analysis was also performed for controlled catechol added green tea samples.</subfield>
  </datafield>
</record>
18
3
görüntülenme
indirilme
Görüntülenme 18
İndirme 3
Veri hacmi 666 Bytes
Tekil görüntülenme 17
Tekil indirme 3

Alıntı yap