Dergi makalesi Açık Erişim

Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection

Kalkan, Zeycan; Yence, Merve; Turk, Fatih; Bektas, Tamer U.; Ozturk, Soner; Surdem, Sedat; Yildirim-Tirgil, Nimet


JSON-LD (schema.org)

{
  "@context": "https://schema.org/", 
  "@id": 232646, 
  "@type": "ScholarlyArticle", 
  "creator": [
    {
      "@type": "Person", 
      "affiliation": "Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Mat Engn, Ankara, Turkey", 
      "name": "Kalkan, Zeycan"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Boron Res Inst, TENMAK, Ankara, Turkey", 
      "name": "Yence, Merve"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Mat Engn, Ankara, Turkey", 
      "name": "Turk, Fatih"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Ankara Yildirim Beyazit Univ, Fac Engn & Nat Sci, Mat Engn, Ankara, Turkey", 
      "name": "Bektas, Tamer U."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Boron Res Inst, TENMAK, Ankara, Turkey", 
      "name": "Ozturk, Soner"
    }, 
    {
      "@type": "Person", 
      "affiliation": "Boron Res Inst, TENMAK, Ankara, Turkey", 
      "name": "Surdem, Sedat"
    }, 
    {
      "@type": "Person", 
      "name": "Yildirim-Tirgil, Nimet"
    }
  ], 
  "datePublished": "2022-01-01", 
  "description": "In this research, an electrochemical enzymatic biosensor system for sensitive and selective catechol detection was developed with using boric acid substituted Polyaniline film coated two different electrodes; gold screen-printed electrode and glassy carbon electrode. Electropolymerization of 3-aminophenylboronic acid is carried out through various electropolymerization conditions, and the best conditions for biosensors systems are concluded. The developed tyrosinase enzyme-based biosensor system is used for the determination of catechol. The limit of detections(LOD) of the developed biosensor was 0.25 mu M and 1.8 mu M with Au SPE and GCE systems, respectively. Additionally, real sample analysis was also performed for controlled catechol added green tea samples.", 
  "headline": "Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection", 
  "identifier": 232646, 
  "image": "https://aperta.ulakbim.gov.tr/static/img/logo/aperta_logo_with_icon.svg", 
  "license": "http://www.opendefinition.org/licenses/cc-by", 
  "name": "Boronic Acid Substituted Polyaniline Based Enzymatic Biosensor System for Catechol Detection", 
  "url": "https://aperta.ulakbim.gov.tr/record/232646"
}
18
3
görüntülenme
indirilme
Görüntülenme 18
İndirme 3
Veri hacmi 666 Bytes
Tekil görüntülenme 17
Tekil indirme 3

Alıntı yap