Konferans bildirisi Açık Erişim

International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency

Draxler, K.; Styblikova, R.; Rietveld, G.; van den Brom, H.; Schnaitt, M.; Waldmann, W.; Dimitrov, E.; Cincar-Vujovic, T.; Paczek, B.; Sadkowski, G.; Crotti, G.; Martin, R.; Garnacho, F.; Blanc, I.; Kampfer, R.; Mester, C.; Wheaton, A.; Mohns, E.; Bergman, A.; Hammarquist, M.; Hammarquist, M.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Styblikova, R.</subfield>
    <subfield code="u">CMI, Brno, Czech Republic</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Rietveld, G.</subfield>
    <subfield code="u">VSL, Delft, Netherlands</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">van den Brom, H.</subfield>
    <subfield code="u">VSL, Delft, Netherlands</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Schnaitt, M.</subfield>
    <subfield code="u">BEV, Villach, Austria</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Waldmann, W.</subfield>
    <subfield code="u">BEV, Villach, Austria</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Dimitrov, E.</subfield>
    <subfield code="u">BIM, Sofia, Bulgaria</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Cincar-Vujovic, T.</subfield>
    <subfield code="u">DMDM, Belgrade, Serbia</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Paczek, B.</subfield>
    <subfield code="u">GUM, Warsaw, Poland</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Sadkowski, G.</subfield>
    <subfield code="u">GUM, Warsaw, Poland</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Crotti, G.</subfield>
    <subfield code="u">INRIM, Turin, Italy</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Martin, R.</subfield>
    <subfield code="u">LCOE, Madrid, Spain</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Garnacho, F.</subfield>
    <subfield code="u">LCOE, Madrid, Spain</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Blanc, I.</subfield>
    <subfield code="u">LNE, Paris, France</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Kampfer, R.</subfield>
    <subfield code="u">METAS, Koniz, Switzerland</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Mester, C.</subfield>
    <subfield code="u">METAS, Koniz, Switzerland</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Wheaton, A.</subfield>
    <subfield code="u">NPL, Teddington, Middx, England</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Mohns, E.</subfield>
    <subfield code="u">PTB, Braunschweig, Germany</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Bergman, A.</subfield>
    <subfield code="u">SP, Gothenburg, Sweden</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Hammarquist, M.</subfield>
    <subfield code="u">SP, Gothenburg, Sweden</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Hammarquist, M.</subfield>
    <subfield code="u">SP, Gothenburg, Sweden</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.81043/aperta.98710</subfield>
    <subfield code="n">doi</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.81043/aperta.98711</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Draxler, K.</subfield>
    <subfield code="u">Czech Tech Univ, Prague, Czech Republic</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:98711</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2016-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/98711/files/bib-03f39f65-2588-4fc2-8f33-0eac142e83d8.txt</subfield>
    <subfield code="z">md5:e0288b6cb463a5859f900ed4bfeeb79f</subfield>
    <subfield code="s">456</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210316140150.0</controlfield>
  <controlfield tag="001">98711</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="a">2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016)</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation ratios (4, 5, 6, 8, 10) kA/5 A of the travelling CT at nominal burden of 5 VA and 15 VA indicate good agreement between the participating laboratories. The main differences are found for phase displacement, at least partly caused by the instability of the traveling standard.</subfield>
  </datafield>
</record>
27
7
görüntülenme
indirilme
Görüntülenme 27
İndirme 7
Veri hacmi 3.2 kB
Tekil görüntülenme 27
Tekil indirme 7

Alıntı yap