Konferans bildirisi Açık Erişim

International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency

Draxler, K.; Styblikova, R.; Rietveld, G.; van den Brom, H.; Schnaitt, M.; Waldmann, W.; Dimitrov, E.; Cincar-Vujovic, T.; Paczek, B.; Sadkowski, G.; Crotti, G.; Martin, R.; Garnacho, F.; Blanc, I.; Kampfer, R.; Mester, C.; Wheaton, A.; Mohns, E.; Bergman, A.; Hammarquist, M.; Hammarquist, M.


Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Draxler, K.</dc:creator>
  <dc:creator>Styblikova, R.</dc:creator>
  <dc:creator>Rietveld, G.</dc:creator>
  <dc:creator>van den Brom, H.</dc:creator>
  <dc:creator>Schnaitt, M.</dc:creator>
  <dc:creator>Waldmann, W.</dc:creator>
  <dc:creator>Dimitrov, E.</dc:creator>
  <dc:creator>Cincar-Vujovic, T.</dc:creator>
  <dc:creator>Paczek, B.</dc:creator>
  <dc:creator>Sadkowski, G.</dc:creator>
  <dc:creator>Crotti, G.</dc:creator>
  <dc:creator>Martin, R.</dc:creator>
  <dc:creator>Garnacho, F.</dc:creator>
  <dc:creator>Blanc, I.</dc:creator>
  <dc:creator>Kampfer, R.</dc:creator>
  <dc:creator>Mester, C.</dc:creator>
  <dc:creator>Wheaton, A.</dc:creator>
  <dc:creator>Mohns, E.</dc:creator>
  <dc:creator>Bergman, A.</dc:creator>
  <dc:creator>Hammarquist, M.</dc:creator>
  <dc:creator>Hammarquist, M.</dc:creator>
  <dc:date>2016-01-01</dc:date>
  <dc:description>Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation ratios (4, 5, 6, 8, 10) kA/5 A of the travelling CT at nominal burden of 5 VA and 15 VA indicate good agreement between the participating laboratories. The main differences are found for phase displacement, at least partly caused by the instability of the traveling standard.</dc:description>
  <dc:identifier>https://aperta.ulakbim.gov.trrecord/98711</dc:identifier>
  <dc:identifier>oai:zenodo.org:98711</dc:identifier>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights>
  <dc:title>International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency</dc:title>
  <dc:type>info:eu-repo/semantics/conferencePaper</dc:type>
  <dc:type>publication-conferencepaper</dc:type>
</oai_dc:dc>
27
7
görüntülenme
indirilme
Görüntülenme 27
İndirme 7
Veri hacmi 3.2 kB
Tekil görüntülenme 27
Tekil indirme 7

Alıntı yap