Konferans bildirisi Açık Erişim

International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency

Draxler, K.; Styblikova, R.; Rietveld, G.; van den Brom, H.; Schnaitt, M.; Waldmann, W.; Dimitrov, E.; Cincar-Vujovic, T.; Paczek, B.; Sadkowski, G.; Crotti, G.; Martin, R.; Garnacho, F.; Blanc, I.; Kampfer, R.; Mester, C.; Wheaton, A.; Mohns, E.; Bergman, A.; Hammarquist, M.; Hammarquist, M.


JSON-LD (schema.org)

{
  "@context": "https://schema.org/", 
  "@id": 98711, 
  "@type": "ScholarlyArticle", 
  "creator": [
    {
      "@type": "Person", 
      "affiliation": "Czech Tech Univ, Prague, Czech Republic", 
      "name": "Draxler, K."
    }, 
    {
      "@type": "Person", 
      "affiliation": "CMI, Brno, Czech Republic", 
      "name": "Styblikova, R."
    }, 
    {
      "@type": "Person", 
      "affiliation": "VSL, Delft, Netherlands", 
      "name": "Rietveld, G."
    }, 
    {
      "@type": "Person", 
      "affiliation": "VSL, Delft, Netherlands", 
      "name": "van den Brom, H."
    }, 
    {
      "@type": "Person", 
      "affiliation": "BEV, Villach, Austria", 
      "name": "Schnaitt, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "BEV, Villach, Austria", 
      "name": "Waldmann, W."
    }, 
    {
      "@type": "Person", 
      "affiliation": "BIM, Sofia, Bulgaria", 
      "name": "Dimitrov, E."
    }, 
    {
      "@type": "Person", 
      "affiliation": "DMDM, Belgrade, Serbia", 
      "name": "Cincar-Vujovic, T."
    }, 
    {
      "@type": "Person", 
      "affiliation": "GUM, Warsaw, Poland", 
      "name": "Paczek, B."
    }, 
    {
      "@type": "Person", 
      "affiliation": "GUM, Warsaw, Poland", 
      "name": "Sadkowski, G."
    }, 
    {
      "@type": "Person", 
      "affiliation": "INRIM, Turin, Italy", 
      "name": "Crotti, G."
    }, 
    {
      "@type": "Person", 
      "affiliation": "LCOE, Madrid, Spain", 
      "name": "Martin, R."
    }, 
    {
      "@type": "Person", 
      "affiliation": "LCOE, Madrid, Spain", 
      "name": "Garnacho, F."
    }, 
    {
      "@type": "Person", 
      "affiliation": "LNE, Paris, France", 
      "name": "Blanc, I."
    }, 
    {
      "@type": "Person", 
      "affiliation": "METAS, Koniz, Switzerland", 
      "name": "Kampfer, R."
    }, 
    {
      "@type": "Person", 
      "affiliation": "METAS, Koniz, Switzerland", 
      "name": "Mester, C."
    }, 
    {
      "@type": "Person", 
      "affiliation": "NPL, Teddington, Middx, England", 
      "name": "Wheaton, A."
    }, 
    {
      "@type": "Person", 
      "affiliation": "PTB, Braunschweig, Germany", 
      "name": "Mohns, E."
    }, 
    {
      "@type": "Person", 
      "affiliation": "SP, Gothenburg, Sweden", 
      "name": "Bergman, A."
    }, 
    {
      "@type": "Person", 
      "affiliation": "SP, Gothenburg, Sweden", 
      "name": "Hammarquist, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "SP, Gothenburg, Sweden", 
      "name": "Hammarquist, M."
    }
  ], 
  "datePublished": "2016-01-01", 
  "description": "Current transformers (CTs) are precision devices that scale high currents down to values that can be easily handled by measurement equipment. To support CT applications in revenue metering, a comparison on AC current transformer calibration systems was performed among 15 European national metrology institutes using a precision CT as the travelling device. The first comparison results for the transformation ratios (4, 5, 6, 8, 10) kA/5 A of the travelling CT at nominal burden of 5 VA and 15 VA indicate good agreement between the participating laboratories. The main differences are found for phase displacement, at least partly caused by the instability of the traveling standard.", 
  "headline": "International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency", 
  "identifier": 98711, 
  "image": "https://aperta.ulakbim.gov.tr/static/img/logo/aperta_logo_with_icon.svg", 
  "license": "http://www.opendefinition.org/licenses/cc-by", 
  "name": "International Comparison of Current Transformer Calibration Systems up to 10 kA at 50 Hz Frequency", 
  "url": "https://aperta.ulakbim.gov.tr/record/98711"
}
42
10
görüntülenme
indirilme
Görüntülenme 42
İndirme 10
Veri hacmi 4.6 kB
Tekil görüntülenme 42
Tekil indirme 10

Alıntı yap