Dergi makalesi Açık Erişim
Samedov, F; Durak, M
<?xml version='1.0' encoding='UTF-8'?> <record xmlns="http://www.loc.gov/MARC21/slim"> <leader>00000nam##2200000uu#4500</leader> <datafield tag="260" ind1=" " ind2=" "> <subfield code="c">2004-01-01</subfield> </datafield> <datafield tag="100" ind1=" " ind2=" "> <subfield code="a">Samedov, F</subfield> </datafield> <datafield tag="540" ind1=" " ind2=" "> <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield> <subfield code="a">Creative Commons Attribution</subfield> </datafield> <datafield tag="700" ind1=" " ind2=" "> <subfield code="a">Durak, M</subfield> </datafield> <datafield tag="909" ind1="C" ind2="O"> <subfield code="o">oai:zenodo.org:93741</subfield> <subfield code="p">user-tubitak-adresli-yayinlar</subfield> </datafield> <datafield tag="542" ind1=" " ind2=" "> <subfield code="l">open</subfield> </datafield> <datafield tag="520" ind1=" " ind2=" "> <subfield code="a">Luminous flux calibration facility with an integrating sphere has been installed at the National Metrology Institute of Turkey (UME) in order to realize lumen. A LabView-based computer -controlled electrical system has been developed to operate light sources and to control electrical parameters. Owing to the corrections of the sphere system, inner coating reflectance, spatial non-uniformity, self-absorption factor and interior temperature variations have been characterized. The overall uncertainty in luminous flux measurement has been determined, with an uncertainty of 1.14% (k = 2) in the range between 5-5000 lm.</subfield> </datafield> <datafield tag="024" ind1=" " ind2=" "> <subfield code="a">10.81043/aperta.93741</subfield> <subfield code="2">doi</subfield> </datafield> <controlfield tag="005">20210316125251.0</controlfield> <datafield tag="773" ind1=" " ind2=" "> <subfield code="i">isVersionOf</subfield> <subfield code="a">10.81043/aperta.93740</subfield> <subfield code="n">doi</subfield> </datafield> <datafield tag="245" ind1=" " ind2=" "> <subfield code="a">Realization of luminous flux unit lumen at National Metrology Institute of Turkey (UME)</subfield> </datafield> <datafield tag="909" ind1="C" ind2="4"> <subfield code="n">2</subfield> <subfield code="v">34</subfield> <subfield code="c">265-274</subfield> <subfield code="p">OPTICA APPLICATA</subfield> </datafield> <datafield tag="650" ind1="1" ind2="7"> <subfield code="2">opendefinition.org</subfield> <subfield code="a">cc-by</subfield> </datafield> <controlfield tag="001">93741</controlfield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="a">user-tubitak-adresli-yayinlar</subfield> </datafield> <datafield tag="980" ind1=" " ind2=" "> <subfield code="b">article</subfield> <subfield code="a">publication</subfield> </datafield> <datafield tag="856" ind1="4" ind2=" "> <subfield code="u">https://aperta.ulakbim.gov.trrecord/93741/files/bib-dd70b81d-e6a0-4d14-90e8-443f058b1098.txt</subfield> <subfield code="z">md5:3f7358bb949ac66d12d237feff89c898</subfield> <subfield code="s">154</subfield> </datafield> </record>
Görüntülenme | 133 |
İndirme | 10 |
Veri hacmi | 1.5 kB |
Tekil görüntülenme | 131 |
Tekil indirme | 10 |