Dergi makalesi Açık Erişim

Realization of luminous flux unit lumen at National Metrology Institute of Turkey (UME)

Samedov, F; Durak, M


JSON

{
  "conceptdoi": "10.81043/aperta.93740", 
  "conceptrecid": "93740", 
  "created": "2021-03-16T12:52:51.820864+00:00", 
  "doi": "10.81043/aperta.93741", 
  "files": [
    {
      "bucket": "65db56d2-b348-411c-9ec9-7129fe112851", 
      "checksum": "md5:3f7358bb949ac66d12d237feff89c898", 
      "key": "bib-dd70b81d-e6a0-4d14-90e8-443f058b1098.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/65db56d2-b348-411c-9ec9-7129fe112851/bib-dd70b81d-e6a0-4d14-90e8-443f058b1098.txt"
      }, 
      "size": 154, 
      "type": "txt"
    }
  ], 
  "id": 93741, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93741.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/65db56d2-b348-411c-9ec9-7129fe112851", 
    "conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93740.svg", 
    "conceptdoi": "https://doi.org/10.81043/aperta.93740", 
    "doi": "https://doi.org/10.81043/aperta.93741", 
    "html": "https://aperta.ulakbim.gov.tr/record/93741", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/93741", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/93741"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-adresli-yayinlar"
      }
    ], 
    "creators": [
      {
        "name": "Samedov, F"
      }, 
      {
        "name": "Durak, M"
      }
    ], 
    "description": "Luminous flux calibration facility with an integrating sphere has been installed at the National Metrology Institute of Turkey (UME) in order to realize lumen. A LabView-based computer -controlled electrical system has been developed to operate light sources and to control electrical parameters. Owing to the corrections of the sphere system, inner coating reflectance, spatial non-uniformity, self-absorption factor and interior temperature variations have been characterized. The overall uncertainty in luminous flux measurement has been determined, with an uncertainty of 1.14% (k = 2) in the range between 5-5000 lm.", 
    "doi": "10.81043/aperta.93741", 
    "has_grant": false, 
    "journal": {
      "issue": "2", 
      "pages": "265-274", 
      "title": "OPTICA APPLICATA", 
      "volume": "34"
    }, 
    "license": {
      "id": "cc-by"
    }, 
    "publication_date": "2004-01-01", 
    "related_identifiers": [
      {
        "identifier": "10.81043/aperta.93740", 
        "relation": "isVersionOf", 
        "scheme": "doi"
      }
    ], 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "93741"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "93740"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "article", 
      "title": "Dergi makalesi", 
      "type": "publication"
    }, 
    "title": "Realization of luminous flux unit lumen at National Metrology Institute of Turkey (UME)"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 10.0, 
    "unique_downloads": 10.0, 
    "unique_views": 131.0, 
    "version_downloads": 10.0, 
    "version_unique_downloads": 10.0, 
    "version_unique_views": 130.0, 
    "version_views": 132.0, 
    "version_volume": 1540.0, 
    "views": 133.0, 
    "volume": 1540.0
  }, 
  "updated": "2021-03-16T12:52:51.877110+00:00"
}
133
10
görüntülenme
indirilme
Görüntülenme 133
İndirme 10
Veri hacmi 1.5 kB
Tekil görüntülenme 131
Tekil indirme 10

Alıntı yap