Konferans bildirisi Açık Erişim
Cayci, H.; Ayhan, B.; Kefeli, T.
{ "conceptdoi": "10.81043/aperta.93434", "conceptrecid": "93434", "created": "2021-03-16T12:48:45.936879+00:00", "doi": "10.81043/aperta.93435", "files": [ { "bucket": "d8433896-dffe-4c77-93f8-c8af4eda6a82", "checksum": "md5:bc41b0cc0f8ba57b0f2dc6940b683f4f", "key": "bib-fe05a517-8b10-4ea9-b25e-e98fed35a11a.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/d8433896-dffe-4c77-93f8-c8af4eda6a82/bib-fe05a517-8b10-4ea9-b25e-e98fed35a11a.txt" }, "size": 193, "type": "txt" } ], "id": 93435, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93435.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/d8433896-dffe-4c77-93f8-c8af4eda6a82", "conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93434.svg", "conceptdoi": "https://doi.org/10.81043/aperta.93434", "doi": "https://doi.org/10.81043/aperta.93435", "html": "https://aperta.ulakbim.gov.tr/record/93435", "latest": "https://aperta.ulakbim.gov.tr/api/records/93435", "latest_html": "https://aperta.ulakbim.gov.tr/record/93435" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-adresli-yayinlar" } ], "creators": [ { "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", "name": "Cayci, H." }, { "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", "name": "Ayhan, B." }, { "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", "name": "Kefeli, T." } ], "description": "Existing mobile calibration standard used for on-site calibration of transformer loss measurement systems has been upgraded. Master-slave configuration of programmable power sources is replaced with the external triggering and synchronization method which ensures the system stability below 50 ppm. Resolution in phase-settings between voltage and current generation is now improved about 2-digits down to 1 m degrees. And, measurement results are automatically evaluated with the corrected calibration values of system components.", "doi": "10.81043/aperta.93435", "has_grant": false, "license": { "id": "cc-by" }, "meeting": { "title": "2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018)" }, "publication_date": "2018-01-01", "related_identifiers": [ { "identifier": "10.81043/aperta.93434", "relation": "isVersionOf", "scheme": "doi" } ], "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "93435" }, "parent": { "pid_type": "recid", "pid_value": "93434" } } ] }, "resource_type": { "subtype": "conferencepaper", "title": "Konferans bildirisi", "type": "publication" }, "title": "An Improved Mobile Calibration Standard for Transformer Loss Measurement Systems" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 6.0, "unique_downloads": 6.0, "unique_views": 16.0, "version_downloads": 6.0, "version_unique_downloads": 6.0, "version_unique_views": 16.0, "version_views": 16.0, "version_volume": 1158.0, "views": 16.0, "volume": 1158.0 }, "updated": "2021-03-16T12:48:45.980653+00:00" }
Görüntülenme | 16 |
İndirme | 6 |
Veri hacmi | 1.2 kB |
Tekil görüntülenme | 16 |
Tekil indirme | 6 |