Konferans bildirisi Açık Erişim

An Improved Mobile Calibration Standard for Transformer Loss Measurement Systems

Cayci, H.; Ayhan, B.; Kefeli, T.


JSON

{
  "conceptdoi": "10.81043/aperta.93434", 
  "conceptrecid": "93434", 
  "created": "2021-03-16T12:48:45.936879+00:00", 
  "doi": "10.81043/aperta.93435", 
  "files": [
    {
      "bucket": "d8433896-dffe-4c77-93f8-c8af4eda6a82", 
      "checksum": "md5:bc41b0cc0f8ba57b0f2dc6940b683f4f", 
      "key": "bib-fe05a517-8b10-4ea9-b25e-e98fed35a11a.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/d8433896-dffe-4c77-93f8-c8af4eda6a82/bib-fe05a517-8b10-4ea9-b25e-e98fed35a11a.txt"
      }, 
      "size": 193, 
      "type": "txt"
    }
  ], 
  "id": 93435, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93435.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/d8433896-dffe-4c77-93f8-c8af4eda6a82", 
    "conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.93434.svg", 
    "conceptdoi": "https://doi.org/10.81043/aperta.93434", 
    "doi": "https://doi.org/10.81043/aperta.93435", 
    "html": "https://aperta.ulakbim.gov.tr/record/93435", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/93435", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/93435"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-adresli-yayinlar"
      }
    ], 
    "creators": [
      {
        "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", 
        "name": "Cayci, H."
      }, 
      {
        "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", 
        "name": "Ayhan, B."
      }, 
      {
        "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey", 
        "name": "Kefeli, T."
      }
    ], 
    "description": "Existing mobile calibration standard used for on-site calibration of transformer loss measurement systems has been upgraded. Master-slave configuration of programmable power sources is replaced with the external triggering and synchronization method which ensures the system stability below 50 ppm. Resolution in phase-settings between voltage and current generation is now improved about 2-digits down to 1 m degrees. And, measurement results are automatically evaluated with the corrected calibration values of system components.", 
    "doi": "10.81043/aperta.93435", 
    "has_grant": false, 
    "license": {
      "id": "cc-by"
    }, 
    "meeting": {
      "title": "2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018)"
    }, 
    "publication_date": "2018-01-01", 
    "related_identifiers": [
      {
        "identifier": "10.81043/aperta.93434", 
        "relation": "isVersionOf", 
        "scheme": "doi"
      }
    ], 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "93435"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "93434"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "conferencepaper", 
      "title": "Konferans bildirisi", 
      "type": "publication"
    }, 
    "title": "An Improved Mobile Calibration Standard for Transformer Loss Measurement Systems"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 6.0, 
    "unique_downloads": 6.0, 
    "unique_views": 16.0, 
    "version_downloads": 6.0, 
    "version_unique_downloads": 6.0, 
    "version_unique_views": 16.0, 
    "version_views": 16.0, 
    "version_volume": 1158.0, 
    "views": 16.0, 
    "volume": 1158.0
  }, 
  "updated": "2021-03-16T12:48:45.980653+00:00"
}
16
6
görüntülenme
indirilme
Görüntülenme 16
İndirme 6
Veri hacmi 1.2 kB
Tekil görüntülenme 16
Tekil indirme 6

Alıntı yap