Konferans bildirisi Açık Erişim
Cayci, H.; Ayhan, B.; Kefeli, T.
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/93435</identifier> <creators> <creator> <creatorName>Cayci, H.</creatorName> <givenName>H.</givenName> <familyName>Cayci</familyName> <affiliation>TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</affiliation> </creator> <creator> <creatorName>Ayhan, B.</creatorName> <givenName>B.</givenName> <familyName>Ayhan</familyName> <affiliation>TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</affiliation> </creator> <creator> <creatorName>Kefeli, T.</creatorName> <givenName>T.</givenName> <familyName>Kefeli</familyName> <affiliation>TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</affiliation> </creator> </creators> <titles> <title>An Improved Mobile Calibration Standard For Transformer Loss Measurement Systems</title> </titles> <publisher>Aperta</publisher> <publicationYear>2018</publicationYear> <dates> <date dateType="Issued">2018-01-01</date> </dates> <resourceType resourceTypeGeneral="Text">Conference paper</resourceType> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/93435</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.81043/aperta.93434</relatedIdentifier> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.81043/aperta.93435</relatedIdentifier> </relatedIdentifiers> <rightsList> <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract">Existing mobile calibration standard used for on-site calibration of transformer loss measurement systems has been upgraded. Master-slave configuration of programmable power sources is replaced with the external triggering and synchronization method which ensures the system stability below 50 ppm. Resolution in phase-settings between voltage and current generation is now improved about 2-digits down to 1 m degrees. And, measurement results are automatically evaluated with the corrected calibration values of system components.</description> </descriptions> </resource>
Görüntülenme | 16 |
İndirme | 6 |
Veri hacmi | 1.2 kB |
Tekil görüntülenme | 16 |
Tekil indirme | 6 |