Dergi makalesi Açık Erişim
Goren, Ahmet C.; Sahin, Gozde; Gumilcineli, Ismail; Binici, Burcu
<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
<identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/93197</identifier>
<creators>
<creator>
<creatorName>Goren, Ahmet C.</creatorName>
<givenName>Ahmet C.</givenName>
<familyName>Goren</familyName>
<affiliation>TUBITAK UME Natl Metrol Inst, Organ Chem Labs, TR-41470 Gebze, Turkey</affiliation>
</creator>
<creator>
<creatorName>Sahin, Gozde</creatorName>
<givenName>Gozde</givenName>
<familyName>Sahin</familyName>
<affiliation>Zivak Technol, Gursel Mh Eski Besiktas Cad 44-1-2, TR-34400 Istanbul, Turkey</affiliation>
</creator>
<creator>
<creatorName>Gumilcineli, Ismail</creatorName>
<givenName>Ismail</givenName>
<familyName>Gumilcineli</familyName>
<affiliation>Zivak Technol, Gursel Mh Eski Besiktas Cad 44-1-2, TR-34400 Istanbul, Turkey</affiliation>
</creator>
<creator>
<creatorName>Binici, Burcu</creatorName>
<givenName>Burcu</givenName>
<familyName>Binici</familyName>
</creator>
</creators>
<titles>
<title>Rapid And Reliable 25-Oh Vitamin D2 And 25-Oh Vitamin D3 Measurements By Multitasker Lc-Ms/Ms</title>
</titles>
<publisher>Aperta</publisher>
<publicationYear>2018</publicationYear>
<dates>
<date dateType="Issued">2018-01-01</date>
</dates>
<resourceType resourceTypeGeneral="Text">Journal article</resourceType>
<alternateIdentifiers>
<alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/93197</alternateIdentifier>
</alternateIdentifiers>
<relatedIdentifiers>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.25135/jcm.13.18.02.070</relatedIdentifier>
</relatedIdentifiers>
<rightsList>
<rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
<rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
</rightsList>
<descriptions>
<description descriptionType="Abstract">The 25-OH Vitamin D2 and 25-OH Vitamin D3 measurement method was validated using a Zivak Multitasker Fully Automated Sample Preparation and Injection System coupled to a MS detector. The current method incorporates all sample preparations, SPE clean up procedures, LC and MS facilities into an all in one system. This system can report patient data within 6 minutes including the SPE and Sample preparation and mass spectrometry analysis time. The correlation coefficient of the developed method was greater than 0.99 for measurands, 25-OH-vitamin Ds, in the calibration range. The measurement uncertainty of the measurements were evaluated and found as 7.7 % and 7.6 % for 25-OH vitamin D2 and 25-OH-vitamin D3, respectively.</description>
</descriptions>
</resource>
| Görüntülenme | 69 |
| İndirme | 57 |
| Veri hacmi | 43.8 MB |
| Tekil görüntülenme | 67 |
| Tekil indirme | 56 |