Konferans bildirisi Açık Erişim
Alshamrani, O. A.; Alrobaish, A. M.; Alqahtani, M. M.; Altakrouni, M. S.; Turhan, E.; Gulmez, G.
<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
<identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/93097</identifier>
<creators>
<creator>
<creatorName>Alshamrani, O. A.</creatorName>
<givenName>O. A.</givenName>
<familyName>Alshamrani</familyName>
<affiliation>Natl Measurement & Calibrat Ctr, POB 3437, Riyadh 11471, Saudi Arabia</affiliation>
</creator>
<creator>
<creatorName>Alrobaish, A. M.</creatorName>
<givenName>A. M.</givenName>
<familyName>Alrobaish</familyName>
<affiliation>Natl Measurement & Calibrat Ctr, POB 3437, Riyadh 11471, Saudi Arabia</affiliation>
</creator>
<creator>
<creatorName>Alqahtani, M. M.</creatorName>
<givenName>M. M.</givenName>
<familyName>Alqahtani</familyName>
<affiliation>Natl Measurement & Calibrat Ctr, POB 3437, Riyadh 11471, Saudi Arabia</affiliation>
</creator>
<creator>
<creatorName>Altakrouni, M. S.</creatorName>
<givenName>M. S.</givenName>
<familyName>Altakrouni</familyName>
<affiliation>Natl Measurement & Calibrat Ctr, POB 3437, Riyadh 11471, Saudi Arabia</affiliation>
</creator>
<creator>
<creatorName>Turhan, E.</creatorName>
<givenName>E.</givenName>
<familyName>Turhan</familyName>
<affiliation>TUBITAK, UME, PK 54, TR-41470 Gebze, Kocaeil, Turkey</affiliation>
</creator>
<creator>
<creatorName>Gulmez, G.</creatorName>
<givenName>G.</givenName>
<familyName>Gulmez</familyName>
<affiliation>TUBITAK, UME, PK 54, TR-41470 Gebze, Kocaeil, Turkey</affiliation>
</creator>
</creators>
<titles>
<title>Construction Of Maxwell-Wien Bridge At Saso-Nmcc</title>
</titles>
<publisher>Aperta</publisher>
<publicationYear>2018</publicationYear>
<dates>
<date dateType="Issued">2018-01-01</date>
</dates>
<resourceType resourceTypeGeneral="Text">Conference paper</resourceType>
<alternateIdentifiers>
<alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/93097</alternateIdentifier>
</alternateIdentifiers>
<relatedIdentifiers>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.81043/aperta.93096</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.81043/aperta.93097</relatedIdentifier>
</relatedIdentifiers>
<rightsList>
<rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
<rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
</rightsList>
<descriptions>
<description descriptionType="Abstract">An inductance calibration system for standard inductors based on a Maxwell-Wien bridge has been constructed at Saudi Standards Metrology and Quality Organization, National Measurement and Calibration Center (SASO NMCC). Expanded measurement uncertainty has been estimated to be less than 20 mu H/H for 100 mH inductance at 1 kHz. A bilateral comparison between SASO NMCC and TUBITAK UME has been performed in order to evaluate the performance of the calibration system.</description>
</descriptions>
</resource>
| Görüntülenme | 41 |
| İndirme | 11 |
| Veri hacmi | 2.3 kB |
| Tekil görüntülenme | 40 |
| Tekil indirme | 11 |