Dergi makalesi Açık Erişim

Performance of a three-dimensional-printed microscanner in a laser scanning microscopy application

Oyman, Hilmi Artun; Gokdel, Yigit Daghan; Ferhanoglu, Onur; Yalcinkaya, Arda Deniz


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2018-01-01</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Oyman, Hilmi Artun</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Istanbul Bilgi Univ, Dept Elect &amp; Elect Engn, Istanbul, Turkey</subfield>
    <subfield code="a">Gokdel, Yigit Daghan</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Istanbul Tech Univ, Dept Elect &amp; Commun Engn, Istanbul, Turkey</subfield>
    <subfield code="a">Ferhanoglu, Onur</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Bogazici Univ, Dept Elect &amp; Elect Engn, Istanbul, Turkey</subfield>
    <subfield code="a">Yalcinkaya, Arda Deniz</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:33181</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">A magnetically actuated microscanner is used in a laser scanning microscopy application. Stress distribution along the circular-profiled flexure is compared with a rectangular counterpart in finite-element environment. Magnetic actuation mechanism of the scanning unit is explained in detail. Moreover, reliability of the scanner is tested for 3 x 10(6) cycle. The scanning device is designed to meet a confocal microscopy application providing 100 mu m x 100 mu m field of view and &amp;lt;3 mu m lateral resolution. The resonance frequencies of the device were analytically modeled, where we obtained 130- and 268-Hz resonance values for the out-of-plane and torsion modes, respectively. The scanning device provided an optical scan angle about 2.5 deg for 170-mA drive current, enabling the desired field of view for our custom built confocal microscope setup. Finally, imaging experiments were conducted on a resolution target, showcasing the desired scan area and resolution. (C) 2018 Society of Photo-Optical Instrumentation Engineers (SPIE)</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1117/1.OE.57.4.041405</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <controlfield tag="005">20210315185209.0</controlfield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Performance of a three-dimensional-printed microscanner in a laser scanning microscopy application</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="n">4</subfield>
    <subfield code="p">OPTICAL ENGINEERING</subfield>
    <subfield code="v">57</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <controlfield tag="001">33181</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="b">article</subfield>
    <subfield code="a">publication</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/33181/files/bib-3ca27fdc-cef9-4885-8b02-ac8a8ef3f04a.txt</subfield>
    <subfield code="z">md5:12642e6f7e3807426c9c861a21c2b010</subfield>
    <subfield code="s">190</subfield>
  </datafield>
</record>
32
12
görüntülenme
indirilme
Görüntülenme 32
İndirme 12
Veri hacmi 2.3 kB
Tekil görüntülenme 29
Tekil indirme 12

Alıntı yap

Oyman, H. A., Gokdel, Y. D., Ferhanoglu, O. ve Yalcinkaya, A. D. (2018). Performance of a three-dimensional-printed microscanner in a laser scanning microscopy application. OPTICAL ENGINEERING, 57(4). doi:10.1117/1.OE.57.4.041405