Dergi makalesi Açık Erişim

Comparison of Air Temperature Calibrations

Heinonen, M.; Anagnostou, M.; Bartolo, J.; Bell, S.; Benyon, R.; Bergerud, R. A.; Bojkovski, J.; Boese, N.; Dinu, C.; Smorgon, D.; Flakiewicz, K.; Martin, M. J.; Nedialkov, S.; Nielsen, M. B.; Aytekin, S. Oguz; Otych, J.; Pedersen, M.; Rujan, M.; Testa, N.; Turzo-Andras, E.; Turzo-Andras, E.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Comparison of Air Temperature Calibrations</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">INTERNATIONAL JOURNAL OF THERMOPHYSICS</subfield>
    <subfield code="v">35</subfield>
    <subfield code="n">6-7</subfield>
    <subfield code="c">1251-1272</subfield>
  </datafield>
  <controlfield tag="001">99325</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">European national metrology institutes use calibration systems of various types for calibrating thermometers in air. These were compared to each other for the first time in a project organized by the European Association of National Metrology Institutes (EURAMET). This EURAMET P1061 comparison project had two main objectives: (1) to study the equivalence of calibrations performed by different laboratories and (2) to investigate correlations between calibration methods and achievable uncertainties. The comparison was realized using a pair of 100 platinum resistance thermometer probes connected to a digital thermometer bridge as the transfer standard. The probes had different dimensions and surface properties. The measurements covered the temperature range between and , but each laboratory chose a subrange most relevant to its scope and performed measurements at five nominal temperature points covering the subrange. To enable comparison between the laboratories, comparison reference functions were determined using weighted least-squares fitting. Various effects related to variations in heat transfer conditions were demonstrated but clear correlations to specific characteristics of calibration system were not identified. Calibrations in air and liquid agreed typically within at and . Expanded uncertainties determined by the participants ranged from to and they were shown to be realistic in most cases.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Hellen Inst Metrol EIM, Thessaloniki, Greece</subfield>
    <subfield code="a">Anagnostou, M.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">MCCA SMI, Kordin, Malta</subfield>
    <subfield code="a">Bartolo, J.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">NPL, Teddington, Middx, England</subfield>
    <subfield code="a">Bell, S.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">INTA, Madrid, Spain</subfield>
    <subfield code="a">Benyon, R.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Norwegian Metrol Serv JV, Oslo, Norway</subfield>
    <subfield code="a">Bergerud, R. A.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Univ Ljubljana, Fac Elect Engn MIRS UL FE LMK, Ljubljana, Slovenia</subfield>
    <subfield code="a">Bojkovski, J.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">PTB, Braunschweig, Germany</subfield>
    <subfield code="a">Boese, N.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Natl Inst Metrol BRML INM, Bucharest, Romania</subfield>
    <subfield code="a">Dinu, C.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Ist Nazl Ric Metrol INRIM, Turin, Italy</subfield>
    <subfield code="a">Smorgon, D.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Cent Off Measures GUM, Warsaw, Poland</subfield>
    <subfield code="a">Flakiewicz, K.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">CEM, Madrid, Spain</subfield>
    <subfield code="a">Martin, M. J.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">BIM, Sofia, Bulgaria</subfield>
    <subfield code="a">Nedialkov, S.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">DTI, Aarhus, Denmark</subfield>
    <subfield code="a">Nielsen, M. B.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">TUBITAK Ulusal Metrol Enstitusu UME, Kocaeli, Turkey</subfield>
    <subfield code="a">Aytekin, S. Oguz</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">CMI, Brno, Czech Republic</subfield>
    <subfield code="a">Otych, J.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">DTI, Aarhus, Denmark</subfield>
    <subfield code="a">Pedersen, M.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Natl Inst Metrol BRML INM, Bucharest, Romania</subfield>
    <subfield code="a">Rujan, M.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">MCCA SMI, Kordin, Malta</subfield>
    <subfield code="a">Testa, N.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Hungarian Trade Licensing Off MKEH, Budapest, Hungary</subfield>
    <subfield code="a">Turzo-Andras, E.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Hungarian Trade Licensing Off MKEH, Budapest, Hungary</subfield>
    <subfield code="a">Turzo-Andras, E.</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="b">article</subfield>
    <subfield code="a">publication</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Ctr Metrol &amp; Accreditat MIKES, Espoo, Finland</subfield>
    <subfield code="a">Heinonen, M.</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2014-01-01</subfield>
  </datafield>
  <controlfield tag="005">20210316141026.0</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:99325</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="z">md5:86e307347224b9896d65c68bf769f560</subfield>
    <subfield code="s">374</subfield>
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/99325/files/bib-e8da50a4-08ab-4136-8ad9-37e7cc37a174.txt</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1007/s10765-014-1654-9</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
</record>
25
10
görüntülenme
indirilme
Görüntülenme 25
İndirme 10
Veri hacmi 3.7 kB
Tekil görüntülenme 25
Tekil indirme 10

Alıntı yap