Dergi makalesi Açık Erişim

Comparison of Air Temperature Calibrations

Heinonen, M.; Anagnostou, M.; Bartolo, J.; Bell, S.; Benyon, R.; Bergerud, R. A.; Bojkovski, J.; Boese, N.; Dinu, C.; Smorgon, D.; Flakiewicz, K.; Martin, M. J.; Nedialkov, S.; Nielsen, M. B.; Aytekin, S. Oguz; Otych, J.; Pedersen, M.; Rujan, M.; Testa, N.; Turzo-Andras, E.; Turzo-Andras, E.


JSON-LD (schema.org)

{
  "@context": "https://schema.org/", 
  "@id": 99325, 
  "@type": "ScholarlyArticle", 
  "creator": [
    {
      "@type": "Person", 
      "affiliation": "Ctr Metrol & Accreditat MIKES, Espoo, Finland", 
      "name": "Heinonen, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Hellen Inst Metrol EIM, Thessaloniki, Greece", 
      "name": "Anagnostou, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "MCCA SMI, Kordin, Malta", 
      "name": "Bartolo, J."
    }, 
    {
      "@type": "Person", 
      "affiliation": "NPL, Teddington, Middx, England", 
      "name": "Bell, S."
    }, 
    {
      "@type": "Person", 
      "affiliation": "INTA, Madrid, Spain", 
      "name": "Benyon, R."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Norwegian Metrol Serv JV, Oslo, Norway", 
      "name": "Bergerud, R. A."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Univ Ljubljana, Fac Elect Engn MIRS UL FE LMK, Ljubljana, Slovenia", 
      "name": "Bojkovski, J."
    }, 
    {
      "@type": "Person", 
      "affiliation": "PTB, Braunschweig, Germany", 
      "name": "Boese, N."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Natl Inst Metrol BRML INM, Bucharest, Romania", 
      "name": "Dinu, C."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Ist Nazl Ric Metrol INRIM, Turin, Italy", 
      "name": "Smorgon, D."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Cent Off Measures GUM, Warsaw, Poland", 
      "name": "Flakiewicz, K."
    }, 
    {
      "@type": "Person", 
      "affiliation": "CEM, Madrid, Spain", 
      "name": "Martin, M. J."
    }, 
    {
      "@type": "Person", 
      "affiliation": "BIM, Sofia, Bulgaria", 
      "name": "Nedialkov, S."
    }, 
    {
      "@type": "Person", 
      "affiliation": "DTI, Aarhus, Denmark", 
      "name": "Nielsen, M. B."
    }, 
    {
      "@type": "Person", 
      "affiliation": "TUBITAK Ulusal Metrol Enstitusu UME, Kocaeli, Turkey", 
      "name": "Aytekin, S. Oguz"
    }, 
    {
      "@type": "Person", 
      "affiliation": "CMI, Brno, Czech Republic", 
      "name": "Otych, J."
    }, 
    {
      "@type": "Person", 
      "affiliation": "DTI, Aarhus, Denmark", 
      "name": "Pedersen, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Natl Inst Metrol BRML INM, Bucharest, Romania", 
      "name": "Rujan, M."
    }, 
    {
      "@type": "Person", 
      "affiliation": "MCCA SMI, Kordin, Malta", 
      "name": "Testa, N."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Hungarian Trade Licensing Off MKEH, Budapest, Hungary", 
      "name": "Turzo-Andras, E."
    }, 
    {
      "@type": "Person", 
      "affiliation": "Hungarian Trade Licensing Off MKEH, Budapest, Hungary", 
      "name": "Turzo-Andras, E."
    }
  ], 
  "datePublished": "2014-01-01", 
  "description": "European national metrology institutes use calibration systems of various types for calibrating thermometers in air. These were compared to each other for the first time in a project organized by the European Association of National Metrology Institutes (EURAMET). This EURAMET P1061 comparison project had two main objectives: (1) to study the equivalence of calibrations performed by different laboratories and (2) to investigate correlations between calibration methods and achievable uncertainties. The comparison was realized using a pair of 100 platinum resistance thermometer probes connected to a digital thermometer bridge as the transfer standard. The probes had different dimensions and surface properties. The measurements covered the temperature range between and , but each laboratory chose a subrange most relevant to its scope and performed measurements at five nominal temperature points covering the subrange. To enable comparison between the laboratories, comparison reference functions were determined using weighted least-squares fitting. Various effects related to variations in heat transfer conditions were demonstrated but clear correlations to specific characteristics of calibration system were not identified. Calibrations in air and liquid agreed typically within at and . Expanded uncertainties determined by the participants ranged from to and they were shown to be realistic in most cases.", 
  "headline": "Comparison of Air Temperature Calibrations", 
  "identifier": 99325, 
  "image": "https://aperta.ulakbim.gov.tr/static/img/logo/aperta_logo_with_icon.svg", 
  "license": "http://www.opendefinition.org/licenses/cc-by", 
  "name": "Comparison of Air Temperature Calibrations", 
  "url": "https://aperta.ulakbim.gov.tr/record/99325"
}
25
10
görüntülenme
indirilme
Görüntülenme 25
İndirme 10
Veri hacmi 3.7 kB
Tekil görüntülenme 25
Tekil indirme 10

Alıntı yap