  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Radiated immunity testing is one of common applications performed in reverberation chambers as per many EMC standards such as IEC 61000-4-21, DO160F, DO160G and MIL-STD461F. Although there are a good number of standards that support EMC testing in reverberation chambers, there are differences in analysis and application methods between them, which may lead to discrepancies in test results. In this research, we theoretically focused on differences between the most prominent EMC standards and thereafter experimentally showed the discrepancies in terms of forward power test values which emerge as a result of the analysis and which are injected into the chamber during testing for the frequency range from 200 MHz to 1 GHz.</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="a">2017 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC)</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.81043/aperta.98368</subfield>
    <subfield code="n">doi</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Cakir, Soydan</subfield>
    <subfield code="u">TUBITAK UME, EMC Lab, Natl Metrol Inst, Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="z">md5:9ba21e6ddf2e2197a4298865d4922d1b</subfield>
    <subfield code="s">203</subfield>
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/98369/files/bib-32973f1a-5cd8-4837-9c6d-4e2079096a12.txt</subfield>
  </datafield>
  <controlfield tag="005">20210316135700.0</controlfield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2017-01-01</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.81043/aperta.98369</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Comparison of Test Standards for Immunity Testing in Reverberation Chambers</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Aslan, Caglar</subfield>
    <subfield code="u">TUBITAK UME, EMC Lab, Natl Metrol Inst, Gebze, Kocaeli, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Leferink, Frank</subfield>
    <subfield code="u">Univ Twente, Telecommun Engn Grp, Enschede, Netherlands</subfield>
  </datafield>
  <controlfield tag="001">98369</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
</record>
49
12
görüntülenme
indirilme
Görüntülenme 49
İndirme 12
Veri hacmi 2.4 kB
Tekil görüntülenme 45
Tekil indirme 12

Alıntı yap