Dergi makalesi Açık Erişim
An, Betul; Can, Suleyman Z.; Bakirdere, Sezgin
<?xml version='1.0' encoding='utf-8'?> <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"> <dc:creator>An, Betul</dc:creator> <dc:creator>Can, Suleyman Z.</dc:creator> <dc:creator>Bakirdere, Sezgin</dc:creator> <dc:date>2020-01-01</dc:date> <dc:description>Accurate quantification of iron is crucial for the characterization of a candidate seawater certified reference material. Isotope dilution mass spectrometry as a primary method is one of the option for this purpose. In this study, triethylamine (TEA) assisted Mg(OH)(2) co-precipitation is developed and combined with isotope dilution mass spectrometry for the characterization of candidate certified reference material, UME CRM 1206. The analytical protocol of co-precipitation was optimized to achieve reproducible yields of similar to 100% Fe with high salt rejection (residual salinity similar to 0.003%). Three calibration strategies, single, double and triple isotope dilution mass spectrometry (IDMS) coupled with co-precipitation were investigated in terms of metrological aspects. The determination of Fe was carried out by ICP-MS with tandem configuration (ICP-MS/MS) using NH3/He cell gas which was optimized for the minimum background equivalence concentration to be able to measure highly accurate Fe-56/Fe-57 ratio with the highest possible sensitivity. The background corrected typical procedural blank levels and limit of detection calculated based on three times the standard deviation of blanks were found as 9 ng/kg (0.16 nM) and 11 ng/kg (0.20 nM) for single IDMS, respectively. Trueness of the developed analytical methods has been demonstrated using CASS-6 and NMIA MX014 with complete and very precise recoveries. SI-traceable values with combined uncertainty (k = 2) were obtained for single, double and triple IDMS as (12.70 +/- 0.16) ng/g, (12.728 +/- 0.084) ng/g and (12.732 +/- 0.062) ng/g, respectively. The relative combined uncertainty for each approach was calculated as 0.64%, 0.33% and 0.24%, respectively.</dc:description> <dc:identifier>https://aperta.ulakbim.gov.trrecord/91191</dc:identifier> <dc:identifier>oai:zenodo.org:91191</dc:identifier> <dc:rights>info:eu-repo/semantics/openAccess</dc:rights> <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights> <dc:source>TALANTA 209</dc:source> <dc:title>Traceable and accurate quantification of iron in seawater using isotope dilution calibration strategies by triple quadrupole ICP-MS/MS: Characterization measurements of iron in a candidate seawater CRM</dc:title> <dc:type>info:eu-repo/semantics/article</dc:type> <dc:type>publication-article</dc:type> </oai_dc:dc>
Görüntülenme | 20 |
İndirme | 8 |
Veri hacmi | 2.1 kB |
Tekil görüntülenme | 20 |
Tekil indirme | 8 |