Dergi makalesi Açık Erişim

Traceable and accurate quantification of iron in seawater using isotope dilution calibration strategies by triple quadrupole ICP-MS/MS: Characterization measurements of iron in a candidate seawater CRM

An, Betul; Can, Suleyman Z.; Bakirdere, Sezgin


JSON

{
  "conceptrecid": "91190", 
  "created": "2021-03-16T12:17:40.557538+00:00", 
  "doi": "10.1016/j.talanta.2019.120503", 
  "files": [
    {
      "bucket": "d2ecff96-86ba-44aa-9eed-47aa619b4977", 
      "checksum": "md5:2cde0b59b46cd5bca377003640473ba3", 
      "key": "bib-4d50f34f-3a42-48c8-ba5d-909a92c8e644.txt", 
      "links": {
        "self": "https://aperta.ulakbim.gov.tr/api/files/d2ecff96-86ba-44aa-9eed-47aa619b4977/bib-4d50f34f-3a42-48c8-ba5d-909a92c8e644.txt"
      }, 
      "size": 262, 
      "type": "txt"
    }
  ], 
  "id": 91191, 
  "links": {
    "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1016/j.talanta.2019.120503.svg", 
    "bucket": "https://aperta.ulakbim.gov.tr/api/files/d2ecff96-86ba-44aa-9eed-47aa619b4977", 
    "doi": "https://doi.org/10.1016/j.talanta.2019.120503", 
    "html": "https://aperta.ulakbim.gov.tr/record/91191", 
    "latest": "https://aperta.ulakbim.gov.tr/api/records/91191", 
    "latest_html": "https://aperta.ulakbim.gov.tr/record/91191"
  }, 
  "metadata": {
    "access_right": "open", 
    "access_right_category": "success", 
    "communities": [
      {
        "id": "tubitak-adresli-yayinlar"
      }
    ], 
    "creators": [
      {
        "name": "An, Betul"
      }, 
      {
        "affiliation": "TUBITAK Natl Metrol Inst, TR-41470 Kocaeli, Turkey", 
        "name": "Can, Suleyman Z."
      }, 
      {
        "affiliation": "Yildiz Tech Univ, Fac Art & Sci, Chem Dept, TR-34210 Istanbul, Turkey", 
        "name": "Bakirdere, Sezgin"
      }
    ], 
    "description": "Accurate quantification of iron is crucial for the characterization of a candidate seawater certified reference material. Isotope dilution mass spectrometry as a primary method is one of the option for this purpose. In this study, triethylamine (TEA) assisted Mg(OH)(2) co-precipitation is developed and combined with isotope dilution mass spectrometry for the characterization of candidate certified reference material, UME CRM 1206. The analytical protocol of co-precipitation was optimized to achieve reproducible yields of similar to 100% Fe with high salt rejection (residual salinity similar to 0.003%). Three calibration strategies, single, double and triple isotope dilution mass spectrometry (IDMS) coupled with co-precipitation were investigated in terms of metrological aspects. The determination of Fe was carried out by ICP-MS with tandem configuration (ICP-MS/MS) using NH3/He cell gas which was optimized for the minimum background equivalence concentration to be able to measure highly accurate Fe-56/Fe-57 ratio with the highest possible sensitivity. The background corrected typical procedural blank levels and limit of detection calculated based on three times the standard deviation of blanks were found as 9 ng/kg (0.16 nM) and 11 ng/kg (0.20 nM) for single IDMS, respectively. Trueness of the developed analytical methods has been demonstrated using CASS-6 and NMIA MX014 with complete and very precise recoveries. SI-traceable values with combined uncertainty (k = 2) were obtained for single, double and triple IDMS as (12.70 +/- 0.16) ng/g, (12.728 +/- 0.084) ng/g and (12.732 +/- 0.062) ng/g, respectively. The relative combined uncertainty for each approach was calculated as 0.64%, 0.33% and 0.24%, respectively.", 
    "doi": "10.1016/j.talanta.2019.120503", 
    "has_grant": false, 
    "journal": {
      "title": "TALANTA", 
      "volume": "209"
    }, 
    "license": {
      "id": "cc-by"
    }, 
    "publication_date": "2020-01-01", 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "91191"
          }, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "91190"
          }
        }
      ]
    }, 
    "resource_type": {
      "subtype": "article", 
      "title": "Dergi makalesi", 
      "type": "publication"
    }, 
    "title": "Traceable and accurate quantification of iron in seawater using isotope dilution calibration strategies by triple quadrupole ICP-MS/MS: Characterization measurements of iron in a candidate seawater CRM"
  }, 
  "owners": [
    1
  ], 
  "revision": 1, 
  "stats": {
    "downloads": 8.0, 
    "unique_downloads": 8.0, 
    "unique_views": 20.0, 
    "version_downloads": 8.0, 
    "version_unique_downloads": 8.0, 
    "version_unique_views": 20.0, 
    "version_views": 20.0, 
    "version_volume": 2096.0, 
    "views": 20.0, 
    "volume": 2096.0
  }, 
  "updated": "2021-03-16T12:17:40.602491+00:00"
}
20
8
görüntülenme
indirilme
Görüntülenme 20
İndirme 8
Veri hacmi 2.1 kB
Tekil görüntülenme 20
Tekil indirme 8

Alıntı yap