Dergi makalesi Açık Erişim
Kallempudi, Sreenivasa Saravan; Altintas, Zeynep; Niazi, Javed H.; Gurbuz, Yasar
<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
<leader>00000nam##2200000uu#4500</leader>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
<subfield code="o">oai:zenodo.org:86701</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">This paper presents the realization of a portable, point-of-care and multi-target immunosensing lab-on-a-chip (LOC). The chip utilizes a novel on-chip actuating mechanism which uses a negative pressure to create thrust inside the channels to facilitate and control the fluid flow. No external instruments and/or sources were used to drive or control the liquid throughout the experimentation. LOC demonstrates a highly sensitive detection and quantification of a cancer marker, human-epidermal growth factor receptor (hEGFR) and a cardiac marker, interleukin 6 (IL-6) by impedimetric measurement approach. Without the use of any signal amplification methods (chemical), a dynamic detection limit of 3-8 ng/ml of hEGFR and 0.1-5 ng/ml of IL-6 in human serum was obtained. The extracted dissociation constants were calculated as 5.86 ng/ml (hEGFR) and 2.45 ng/ml (IL-6) by kinetic analysis. (C) 2012 Elsevier B.V. All rights reserved.</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">publication</subfield>
<subfield code="b">article</subfield>
</datafield>
<datafield tag="540" ind1=" " ind2=" ">
<subfield code="a">Creative Commons Attribution</subfield>
<subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Kallempudi, Sreenivasa Saravan</subfield>
<subfield code="u">Sabanci Univ, Fac Engn & Nat Sci, TR-34956 Istanbul, Turkey</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="z">md5:c3a11159155d08fb106ea26cd769c39f</subfield>
<subfield code="s">208</subfield>
<subfield code="u">https://aperta.ulakbim.gov.trrecord/86701/files/bib-4705c84d-3ae5-480c-9195-2d1549025235.txt</subfield>
</datafield>
<controlfield tag="005">20210316065902.0</controlfield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2012-01-01</subfield>
</datafield>
<datafield tag="024" ind1=" " ind2=" ">
<subfield code="a">10.1016/j.snb.2012.01.034</subfield>
<subfield code="2">doi</subfield>
</datafield>
<datafield tag="542" ind1=" " ind2=" ">
<subfield code="l">open</subfield>
</datafield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">A new microfluidics system with a hand-operated, on-chip actuator for immunosensor applications</subfield>
</datafield>
<datafield tag="909" ind1="C" ind2="4">
<subfield code="v">163</subfield>
<subfield code="p">SENSORS AND ACTUATORS B-CHEMICAL</subfield>
<subfield code="c">194-201</subfield>
<subfield code="n">1</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="7">
<subfield code="a">cc-by</subfield>
<subfield code="2">opendefinition.org</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Altintas, Zeynep</subfield>
<subfield code="u">Sabanci Univ, Fac Engn & Nat Sci, TR-34956 Istanbul, Turkey</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Niazi, Javed H.</subfield>
<subfield code="u">Sabanci Univ, Nanotechnol Res & Applicat Ctr, TR-34956 Istanbul, Turkey</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Gurbuz, Yasar</subfield>
<subfield code="u">Sabanci Univ, Fac Engn & Nat Sci, TR-34956 Istanbul, Turkey</subfield>
</datafield>
<controlfield tag="001">86701</controlfield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
</datafield>
</record>
| Görüntülenme | 63 |
| İndirme | 10 |
| Veri hacmi | 2.1 kB |
| Tekil görüntülenme | 56 |
| Tekil indirme | 9 |