Dergi makalesi Açık Erişim

Effect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape

Ozturk, Ali; Duzgun, Ibrahim; Celebi, Selahattin


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Duzgun, Ibrahim</subfield>
    <subfield code="u">Gumushane Univ, Fac Engn &amp; Nat Sci, Dept Phys Engn, TR-29100 Gumushane, Turkey</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Celebi, Selahattin</subfield>
    <subfield code="u">Karadeniz Tech Univ, Fac Sci &amp; Arts, Dept Phys, TR-61080 Trabzon, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS</subfield>
    <subfield code="v">80</subfield>
    <subfield code="n">3</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1051/epjap/2017170266</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Effect of dc field on ac-loss peak in a commercial Bi:2223/Ag tape</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Ozturk, Ali</subfield>
    <subfield code="u">Karadeniz Tech Univ, Fac Sci &amp; Arts, Dept Phys, TR-61080 Trabzon, Turkey</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:43705</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2017-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/43705/files/bib-a56c9568-e7cc-4420-a51b-215ffe302e42.txt</subfield>
    <subfield code="z">md5:4c1557b9eed69d4e4cff4493f8836b13</subfield>
    <subfield code="s">161</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210315211133.0</controlfield>
  <controlfield tag="001">43705</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Measurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, H-ac, in the presence of bias magnetic field H-dc directed along H-ac are reported. It is found that the peak values of the imaginary component of ac susceptibility x"(max) versus H-ac trace a valley for the orientation where applied field H-a perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression j(c)- alpha(T)/B-n, choice of the bias field H-dc together with selected ac field amplitudes H-ac, and dimension and geometry of sample studied. Our calculations based on critical state model with j(c) - alpha(1 - T/T-cm)(p)/B-n using the fitting parameters of n - 0.25, p- 2.2, T-cm- 108 K gives quite good results to compare the experimental and calculated curves.</subfield>
  </datafield>
</record>
24
5
görüntülenme
indirilme
Görüntülenme 24
İndirme 5
Veri hacmi 805 Bytes
Tekil görüntülenme 24
Tekil indirme 5

Alıntı yap