Dergi makalesi Açık Erişim
Ozturk, Ali; Duzgun, Ibrahim; Celebi, Selahattin
<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
<identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/43705</identifier>
<creators>
<creator>
<creatorName>Ozturk, Ali</creatorName>
<givenName>Ali</givenName>
<familyName>Ozturk</familyName>
<affiliation>Karadeniz Tech Univ, Fac Sci & Arts, Dept Phys, TR-61080 Trabzon, Turkey</affiliation>
</creator>
<creator>
<creatorName>Duzgun, Ibrahim</creatorName>
<givenName>Ibrahim</givenName>
<familyName>Duzgun</familyName>
<affiliation>Gumushane Univ, Fac Engn & Nat Sci, Dept Phys Engn, TR-29100 Gumushane, Turkey</affiliation>
</creator>
<creator>
<creatorName>Celebi, Selahattin</creatorName>
<givenName>Selahattin</givenName>
<familyName>Celebi</familyName>
<affiliation>Karadeniz Tech Univ, Fac Sci & Arts, Dept Phys, TR-61080 Trabzon, Turkey</affiliation>
</creator>
</creators>
<titles>
<title>Effect Of Dc Field On Ac-Loss Peak In A Commercial Bi:2223/Ag Tape</title>
</titles>
<publisher>Aperta</publisher>
<publicationYear>2017</publicationYear>
<dates>
<date dateType="Issued">2017-01-01</date>
</dates>
<resourceType resourceTypeGeneral="Text">Journal article</resourceType>
<alternateIdentifiers>
<alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/43705</alternateIdentifier>
</alternateIdentifiers>
<relatedIdentifiers>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1051/epjap/2017170266</relatedIdentifier>
</relatedIdentifiers>
<rightsList>
<rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
<rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
</rightsList>
<descriptions>
<description descriptionType="Abstract">Measurements of the ac susceptibility in a commercial Bi:2223/Ag tape for some different ac magnetic field amplitudes, H-ac, in the presence of bias magnetic field H-dc directed along H-ac are reported. It is found that the peak values of the imaginary component of ac susceptibility x"(max) versus H-ac trace a valley for the orientation where applied field H-a perpendicular to wide face of the tape total. We note that the observation of the valley depends on various parameters such as field dependence parameter n in the critical current density, in the simple power law expression j(c)- alpha(T)/B-n, choice of the bias field H-dc together with selected ac field amplitudes H-ac, and dimension and geometry of sample studied. Our calculations based on critical state model with j(c) - alpha(1 - T/T-cm)(p)/B-n using the fitting parameters of n - 0.25, p- 2.2, T-cm- 108 K gives quite good results to compare the experimental and calculated curves.</description>
</descriptions>
</resource>
| Görüntülenme | 54 |
| İndirme | 9 |
| Veri hacmi | 1.4 kB |
| Tekil görüntülenme | 48 |
| Tekil indirme | 9 |