Dergi makalesi Açık Erişim

Investigation of energy efficiency of heating systems in power plant boilers for different conditions with CFD analysis

Yildizay, H. D.; Aydin, Oe.; Boeke, Y. Erhan; Uralcan, I. Y.; Sen, F.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Aydin, Oe.</subfield>
    <subfield code="u">Dumlupinar Univ, Dept Mech Engn, TR-43100 Kutahya, Turkiye</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Boeke, Y. Erhan</subfield>
    <subfield code="u">Istanbul Tech Univ, Mech Engn Fac, TR-34437 Istanbul, Turkiye</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Uralcan, I. Y.</subfield>
    <subfield code="u">Istanbul Tech Univ, Mech Engn Fac, TR-34437 Istanbul, Turkiye</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Sen, F.</subfield>
    <subfield code="u">Dumlupinar Univ, Dept Biochem, Sen Res Grp, TR-43000 Kutahya, Turkiye</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY</subfield>
    <subfield code="v">20</subfield>
    <subfield code="n">10</subfield>
    <subfield code="c">8</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1007/s13762-023-05130-1</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Investigation of energy efficiency of heating systems in power plant boilers for different conditions with CFD analysis</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Yildizay, H. D.</subfield>
    <subfield code="u">Dumlupinar Univ, Dept Mech Engn, TR-43100 Kutahya, Turkiye</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:aperta.ulakbim.gov.tr:269782</subfield>
    <subfield code="p">user-tubitak-destekli-proje-yayinlari</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2023-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/269782/files/bib-84d46b8b-5117-4f71-8a77-6ba746705fcb.txt</subfield>
    <subfield code="z">md5:a5b5c2f753bc3cf65329d21e36cee503</subfield>
    <subfield code="s">268</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20240607140418.0</controlfield>
  <controlfield tag="001">269782</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;Flame shape temperature distribution, CO2, and O-2 concentrations in the pulverized coal-fired boiler at Seyitomer Thermal Power Plant are numerically investigated for real operating conditions. The numerical results are compared with the measured results to validate the model. It is observed that the calculated and measured temperature differences are less than 50 K. For both numerical analysis and measurements, a decrease in O-2 concentrations and an increase in CO2 concentrations in the flame zone of the furnace are observed. The flame shape was numerically analyzed for various operating conditions of the burners. It is observed that the flame does not fill the boiler, narrows along the boiler, and disturbs the homogeneity of the temperature distribution for the cases when the opposite burners 2 and 5 are switched off separately. As a result, coal burners should be shut down during operation, considering proper flame formation. This study has provided important information to the literature for more efficient and environmentally friendly coal combustion in thermal power plants.&lt;/p&gt;</subfield>
  </datafield>
</record>
0
0
görüntülenme
indirilme
Görüntülenme 0
İndirme 0
Veri hacmi 0 Bytes
Tekil görüntülenme 0
Tekil indirme 0

Alıntı yap