Dergi makalesi Açık Erişim

Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer

Saleh, S. A.; Ozkop, E.; Valdes, M. E.; Yuksel, A.; Jewett, D.; Al-Durra, A.; Meng, J.; Panetta, S. A. R.


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Ozkop, E.</subfield>
    <subfield code="u">Karadeniz Tech Univ, Dept Elect &amp; Elect Engn, TR-61080 Trabzon, Turkiye</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Valdes, M. E.</subfield>
    <subfield code="u">Asea Brown Boveri, ABB Elect Solut, CH-8050 Zurich, Switzerland</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Yuksel, A.</subfield>
    <subfield code="u">Tubitak Mam, Energy Inst, Ankara Branch, TR-41470 Gebze, Turkiye</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Jewett, D.</subfield>
    <subfield code="u">Univ New Brunswick, Dept Elect &amp; Comp Engn, Fredericton, NB E3B 5A3, Canada</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Al-Durra, A.</subfield>
    <subfield code="u">Khalifa Univ Sci Technol, Dept Elect &amp; Comp Engn, Abu Dhabi 127788, U Arab Emirates</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Meng, J.</subfield>
    <subfield code="u">Univ New Brunswick, Dept Elect &amp; Comp Engn, Fredericton, NB E3B 5A3, Canada</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Panetta, S. A. R.</subfield>
    <subfield code="u">Gard Corp, Dept Engn, Mississauga, ON L4T IL2, Canada</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="p">IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS</subfield>
    <subfield code="v">59</subfield>
    <subfield code="n">2</subfield>
    <subfield code="c">14</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1109/TIA.2022.3233557</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Saleh, S. A.</subfield>
    <subfield code="u">Univ New Brunswick, Dept Elect &amp; Comp Engn, Fredericton, NB E3B 5A3, Canada</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:aperta.ulakbim.gov.tr:265410</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2023-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/265410/files/bib-5f87e736-3419-4367-a384-f8e7e956caab.txt</subfield>
    <subfield code="z">md5:578ec2bdc1698a66885af451a763ec45</subfield>
    <subfield code="s">285</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20240607113319.0</controlfield>
  <controlfield tag="001">265410</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">&lt;p&gt;This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is a new grounding system that is designed to act as a solid-grounding for high frequency currents, and as a low resistance-grounding for low frequency currents. This grounding system is composed from a parallel R - C circuit with an equivalent impedance able to affect system zero-sequence currents and ground potentials. Such effects on zero-sequence currents and ground potentials can directly impact the accuracy and response speed of ground fault protection. Effects of frequency-selective grounding on ground fault protection are experimentally assessed for different fault and non-fault events, when the transformer supplies linear and non-liner loads. Experimental results demonstrate responses of various implementations of ground fault protection to fault and non-fault events, when the protected system has frequency selective grounding. Moreover, presented results and discussions aim to demonstrate the ability of frequency-selective grounding to support the operation of ground fault protection during different loading conditions and fault events.&lt;/p&gt;</subfield>
  </datafield>
</record>
0
0
görüntülenme
indirilme
Görüntülenme 0
İndirme 0
Veri hacmi 0 Bytes
Tekil görüntülenme 0
Tekil indirme 0

Alıntı yap