Dergi makalesi Açık Erişim
Saleh, S. A.; Ozkop, E.; Valdes, M. E.; Yuksel, A.; Jewett, D.; Al-Durra, A.; Meng, J.; Panetta, S. A. R.
<?xml version='1.0' encoding='utf-8'?> <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"> <dc:creator>Saleh, S. A.</dc:creator> <dc:creator>Ozkop, E.</dc:creator> <dc:creator>Valdes, M. E.</dc:creator> <dc:creator>Yuksel, A.</dc:creator> <dc:creator>Jewett, D.</dc:creator> <dc:creator>Al-Durra, A.</dc:creator> <dc:creator>Meng, J.</dc:creator> <dc:creator>Panetta, S. A. R.</dc:creator> <dc:date>2023-01-01</dc:date> <dc:description>This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is a new grounding system that is designed to act as a solid-grounding for high frequency currents, and as a low resistance-grounding for low frequency currents. This grounding system is composed from a parallel R - C circuit with an equivalent impedance able to affect system zero-sequence currents and ground potentials. Such effects on zero-sequence currents and ground potentials can directly impact the accuracy and response speed of ground fault protection. Effects of frequency-selective grounding on ground fault protection are experimentally assessed for different fault and non-fault events, when the transformer supplies linear and non-liner loads. Experimental results demonstrate responses of various implementations of ground fault protection to fault and non-fault events, when the protected system has frequency selective grounding. Moreover, presented results and discussions aim to demonstrate the ability of frequency-selective grounding to support the operation of ground fault protection during different loading conditions and fault events.</dc:description> <dc:identifier>https://aperta.ulakbim.gov.trrecord/265410</dc:identifier> <dc:identifier>oai:aperta.ulakbim.gov.tr:265410</dc:identifier> <dc:rights>info:eu-repo/semantics/openAccess</dc:rights> <dc:rights>http://www.opendefinition.org/licenses/cc-by</dc:rights> <dc:source>IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS 59(2) 14</dc:source> <dc:title>Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer</dc:title> <dc:type>info:eu-repo/semantics/article</dc:type> <dc:type>publication-article</dc:type> </oai_dc:dc>
Görüntülenme | 0 |
İndirme | 0 |
Veri hacmi | 0 Bytes |
Tekil görüntülenme | 0 |
Tekil indirme | 0 |