Dergi makalesi Açık Erişim
Atalay, S.; Inan, O. O.; Kolat, V. S.; Izgi, T.
{ "conceptrecid": "236321", "created": "2022-10-07T09:38:20.947208+00:00", "doi": "10.12693/APhysPolA.139.159", "files": [ { "bucket": "d5ece62a-d6e0-4522-a8a1-4a919bbb400c", "checksum": "md5:d23ece9bc06f259051c3f5374f8a58c5", "key": "bib-e662674a-cf94-4f24-a6a5-e51342120d0b.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/d5ece62a-d6e0-4522-a8a1-4a919bbb400c/bib-e662674a-cf94-4f24-a6a5-e51342120d0b.txt" }, "size": 184, "type": "txt" } ], "id": 236322, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.12693/APhysPolA.139.159.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/d5ece62a-d6e0-4522-a8a1-4a919bbb400c", "doi": "https://doi.org/10.12693/APhysPolA.139.159", "html": "https://aperta.ulakbim.gov.tr/record/236322", "latest": "https://aperta.ulakbim.gov.tr/api/records/236322", "latest_html": "https://aperta.ulakbim.gov.tr/record/236322" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-destekli-proje-yayinlari" } ], "creators": [ { "affiliation": "Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey", "name": "Atalay, S." }, { "affiliation": "Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey", "name": "Inan, O. O." }, { "affiliation": "Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey", "name": "Kolat, V. S." }, { "affiliation": "Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey", "name": "Izgi, T." } ], "description": "In this study, Fe40Ni38Mo4B18 (2826MB) amorphous ferromagnetic ribbons were used as a magnetoelastic sensor. The variation in resonance frequency and quality (Q) factor values of samples with a 30 mm length and different widths is investigated as a function of a magnetic field. It is observed that as the sample width increases, the change in resonance frequency and the Q factor both decrease. The parameter Q x amplitude/M is defined to understand the effect of a ribbon width on the resonance curve. According to this parameter, samples with 1 and 2 mm widths are found to have a better magnetoelastic effect.", "doi": "10.12693/APhysPolA.139.159", "has_grant": false, "journal": { "issue": "2", "pages": "159-163", "title": "ACTA PHYSICA POLONICA A", "volume": "139" }, "license": { "id": "cc-by" }, "publication_date": "2021-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "236322" }, "parent": { "pid_type": "recid", "pid_value": "236321" } } ] }, "resource_type": { "subtype": "article", "title": "Dergi makalesi", "type": "publication" }, "science_branches": [ "Di\u011fer" ], "title": "Influence of Ferromagnetic Ribbon Width on Q Factor and Magnetoelastic Resonance Frequency" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 3.0, "unique_downloads": 3.0, "unique_views": 11.0, "version_downloads": 3.0, "version_unique_downloads": 3.0, "version_unique_views": 11.0, "version_views": 11.0, "version_volume": 552.0, "views": 11.0, "volume": 552.0 }, "updated": "2022-10-07T09:38:21.014458+00:00" }
Görüntülenme | 11 |
İndirme | 3 |
Veri hacmi | 552 Bytes |
Tekil görüntülenme | 11 |
Tekil indirme | 3 |