Dergi makalesi Açık Erişim

Influence of Ferromagnetic Ribbon Width on Q Factor and Magnetoelastic Resonance Frequency

Atalay, S.; Inan, O. O.; Kolat, V. S.; Izgi, T.


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/236322</identifier>
  <creators>
    <creator>
      <creatorName>Atalay, S.</creatorName>
      <givenName>S.</givenName>
      <familyName>Atalay</familyName>
      <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Inan, O. O.</creatorName>
      <givenName>O. O.</givenName>
      <familyName>Inan</familyName>
      <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Kolat, V. S.</creatorName>
      <givenName>V. S.</givenName>
      <familyName>Kolat</familyName>
      <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Izgi, T.</creatorName>
      <givenName>T.</givenName>
      <familyName>Izgi</familyName>
      <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Influence Of Ferromagnetic Ribbon Width On Q Factor And Magnetoelastic Resonance Frequency</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2021</publicationYear>
  <dates>
    <date dateType="Issued">2021-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/236322</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.12693/APhysPolA.139.159</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">In this study, Fe40Ni38Mo4B18 (2826MB) amorphous ferromagnetic ribbons were used as a magnetoelastic sensor. The variation in resonance frequency and quality (Q) factor values of samples with a 30 mm length and different widths is investigated as a function of a magnetic field. It is observed that as the sample width increases, the change in resonance frequency and the Q factor both decrease. The parameter Q x amplitude/M is defined to understand the effect of a ribbon width on the resonance curve. According to this parameter, samples with 1 and 2 mm widths are found to have a better magnetoelastic effect.</description>
  </descriptions>
</resource>
11
3
görüntülenme
indirilme
Görüntülenme 11
İndirme 3
Veri hacmi 552 Bytes
Tekil görüntülenme 11
Tekil indirme 3

Alıntı yap