Dergi makalesi Açık Erişim
Atalay, S.; Inan, O. O.; Kolat, V. S.; Izgi, T.
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/236322</identifier> <creators> <creator> <creatorName>Atalay, S.</creatorName> <givenName>S.</givenName> <familyName>Atalay</familyName> <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation> </creator> <creator> <creatorName>Inan, O. O.</creatorName> <givenName>O. O.</givenName> <familyName>Inan</familyName> <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation> </creator> <creator> <creatorName>Kolat, V. S.</creatorName> <givenName>V. S.</givenName> <familyName>Kolat</familyName> <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation> </creator> <creator> <creatorName>Izgi, T.</creatorName> <givenName>T.</givenName> <familyName>Izgi</familyName> <affiliation>Inonu Univ, Fac Sci, Phys Dept, Malatya, Turkey</affiliation> </creator> </creators> <titles> <title>Influence Of Ferromagnetic Ribbon Width On Q Factor And Magnetoelastic Resonance Frequency</title> </titles> <publisher>Aperta</publisher> <publicationYear>2021</publicationYear> <dates> <date dateType="Issued">2021-01-01</date> </dates> <resourceType resourceTypeGeneral="Text">Journal article</resourceType> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/236322</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.12693/APhysPolA.139.159</relatedIdentifier> </relatedIdentifiers> <rightsList> <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract">In this study, Fe40Ni38Mo4B18 (2826MB) amorphous ferromagnetic ribbons were used as a magnetoelastic sensor. The variation in resonance frequency and quality (Q) factor values of samples with a 30 mm length and different widths is investigated as a function of a magnetic field. It is observed that as the sample width increases, the change in resonance frequency and the Q factor both decrease. The parameter Q x amplitude/M is defined to understand the effect of a ribbon width on the resonance curve. According to this parameter, samples with 1 and 2 mm widths are found to have a better magnetoelastic effect.</description> </descriptions> </resource>
Görüntülenme | 11 |
İndirme | 3 |
Veri hacmi | 552 Bytes |
Tekil görüntülenme | 11 |
Tekil indirme | 3 |