{ "DOI": "10.1063/1.4751629", "abstract": "Radiometric calibration of an imaging telescope is usually made using a uniform illumination sphere in a laboratory. In this study, we used the open-sky images taken during bright day conditions to calibrate our telescope. We found a dark signal offset value and a linear response coefficient value for each pixel by using three different algorithms. Then we applied these coefficients to the taken images, and considerably lowered the image non-uniformity. Calibration can be repeated during the operation of telescope with an object that has better uniformity than open-sky. Also SNR (Signal to Noise Ratio) of each pixel was calculated from the open-sky images using the temporal mean and standard deviations. It is found that SNR is greater than 80 for all pixels even at low light levels.", "author": [ { "family": "Yilmaz", "given": " Ozgur" }, { "family": "Turk", "given": " Fethi" }, { "family": "Selimoglu", "given": " Ozgur" } ], "id": "104459", "issued": { "date-parts": [ [ 2012, 1, 1 ] ] }, "title": "Radiometric Calibration and SNR Calculation of a SWIR Imaging Telescope", "type": "paper-conference" }