Dergi makalesi Açık Erişim
Pektas, I
{
"conceptdoi": "10.81043/aperta.102768",
"conceptrecid": "102768",
"created": "2021-03-16T14:58:05.281744+00:00",
"doi": "10.81043/aperta.102769",
"files": [
{
"bucket": "a7b59b88-5428-486f-90ff-ee01713b5e49",
"checksum": "md5:4fcdc2ea32a81803c5cd3610c82ff52f",
"key": "bib-a24e0239-7415-48f7-8d3f-08293f2fa0bf.txt",
"links": {
"self": "https://aperta.ulakbim.gov.tr/api/files/a7b59b88-5428-486f-90ff-ee01713b5e49/bib-a24e0239-7415-48f7-8d3f-08293f2fa0bf.txt"
},
"size": 135,
"type": "txt"
}
],
"id": 102769,
"links": {
"badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.102769.svg",
"bucket": "https://aperta.ulakbim.gov.tr/api/files/a7b59b88-5428-486f-90ff-ee01713b5e49",
"conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.102768.svg",
"conceptdoi": "https://doi.org/10.81043/aperta.102768",
"doi": "https://doi.org/10.81043/aperta.102769",
"html": "https://aperta.ulakbim.gov.tr/record/102769",
"latest": "https://aperta.ulakbim.gov.tr/api/records/102769",
"latest_html": "https://aperta.ulakbim.gov.tr/record/102769"
},
"metadata": {
"access_right": "open",
"access_right_category": "success",
"communities": [
{
"id": "tubitak-adresli-yayinlar"
}
],
"creators": [
{
"name": "Pektas, I"
}
],
"description": "The thermal degradation of graphite and glass-reinforced phenolic insulators have been studied at high temperature by using thermogravimetric (TGA) and differential scanning calorimetric analyses. TGA analysis was carried out in a stream of pure nitrogen over temperature range ambient to 900 degrees C and DSC analysis to 500 degrees C. A heating rate of 10 degrees C/min was used for the determination of degradation temperature and heating rates of 5, 10, 20, 30, and 50 degrees C/min were used for the estimation of degradation temperature (T-max) of the insulator at high-temperature service and calculation of activation. Activation energy of phenolic resin was calculated as 356 kJ mol(-1) using the Ozawa method. T-max was determined as 661 degrees C for 20% conversion. The specific heat capacity of graphite phenolic was found as 970 J kg(-1) K-1 at 100 degrees C. The half-life of the phenolic resin was determined to be approximately 116.2 s at 3500 degrees C. The thermal analysis has been conducted using transient heat conduction and the in-depth temperature distribution was evaluated along the rocket nozzle. The better insulator thickness, including a safety factor for graphite and E-glass-reinforced phenolics were calculated as 3 and 2 mm, respectively. (C) 1998 John Wiley & Sons, Inc.",
"doi": "10.81043/aperta.102769",
"has_grant": false,
"journal": {
"issue": "8",
"pages": "1337-1342",
"title": "JOURNAL OF APPLIED POLYMER SCIENCE",
"volume": "68"
},
"license": {
"id": "cc-by"
},
"publication_date": "1998-01-01",
"related_identifiers": [
{
"identifier": "10.81043/aperta.102768",
"relation": "isVersionOf",
"scheme": "doi"
}
],
"relations": {
"version": [
{
"count": 1,
"index": 0,
"is_last": true,
"last_child": {
"pid_type": "recid",
"pid_value": "102769"
},
"parent": {
"pid_type": "recid",
"pid_value": "102768"
}
}
]
},
"resource_type": {
"subtype": "article",
"title": "Dergi makalesi",
"type": "publication"
},
"title": "High-temperature degradation of reinforced phenolic insulator"
},
"owners": [
1
],
"revision": 1,
"stats": {
"downloads": 9.0,
"unique_downloads": 9.0,
"unique_views": 41.0,
"version_downloads": 9.0,
"version_unique_downloads": 9.0,
"version_unique_views": 41.0,
"version_views": 44.0,
"version_volume": 1215.0,
"views": 44.0,
"volume": 1215.0
},
"updated": "2021-03-16T14:58:05.330064+00:00"
}
| Görüntülenme | 44 |
| İndirme | 9 |
| Veri hacmi | 1.2 kB |
| Tekil görüntülenme | 41 |
| Tekil indirme | 9 |