Konferans bildirisi Açık Erişim

Comparison of the Input Electrical Power Measurement Methods for HIFU Transducers

Karaboce, Baki; Gulmez, Yakup; Bilgic, Eyup; Sadikoglu, Enver; Ince, Ahmet T.; Skarlatos, Yani


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Comparison of the Input Electrical Power Measurement Methods for HIFU Transducers</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.81043/aperta.99421</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <controlfield tag="001">99421</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">HIFU (High Intensity Focused Ultrasound) transducers are attractive tools for cancer therapy. They must be used carefully for operator and patient safety as they produce very high powers up to a few hundred watts, and characterized in many ways. The ultrasonic power of a transducer is directly proportional to the applied input electrical voltage, current and consequently electrical power. Internationally accepted methods for measurements of ultrasonic output power up to 10 W are well established in the IEC 61161 standards [1]. The same method was used for higher powers up to 150 W with an uncertainty of 4.7% for 1.1 MHz and 5.0% for 3.3 MHz in an intercomparison between national metrology institutes [8]. In this paper, input electrical power of the HIFU transducer, which is mainly converted into ultrasonic energy, was determined. 3 methods for the measurement of electrical power delivered to a reactive ultrasonic (HIFU) transducer were compared. Electrical power measurements were realized with an expanded uncertainty of 3.3 % for up to 50 W and 4.3 % for up to 100 W in the frequency range between 0.93 MHz and 3.1 MHz. Measurement devices were calibrated and verified by establishing traceability to electrical and ultrasonic standards at TUBITAK UME (The Scientific and Technological Research Council of Turkey, National Metrology Institute) primary laboratories. Electrical power measurement results obtained by this method were also compared with two different conventional power meters. Electrical power measurement results detailed in this paper showed an agreement with each other and conventional power meters.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">TUBITAK, Natl Metrol Inst, Kocaeli, Turkey</subfield>
    <subfield code="a">Gulmez, Yakup</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">TUBITAK, Natl Metrol Inst, Kocaeli, Turkey</subfield>
    <subfield code="a">Bilgic, Eyup</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">TUBITAK, Natl Metrol Inst, Kocaeli, Turkey</subfield>
    <subfield code="a">Sadikoglu, Enver</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Yeditepe Univ, Dept Phys, Istanbul, Turkey</subfield>
    <subfield code="a">Ince, Ahmet T.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Bogazi Univ, Dept Phys, Istanbul, Turkey</subfield>
    <subfield code="a">Skarlatos, Yani</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="b">conferencepaper</subfield>
    <subfield code="a">publication</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">TUBITAK, Natl Metrol Inst, Kocaeli, Turkey</subfield>
    <subfield code="a">Karaboce, Baki</subfield>
  </datafield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="a">2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA)</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2014-01-01</subfield>
  </datafield>
  <controlfield tag="005">20210316141149.0</controlfield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="n">doi</subfield>
    <subfield code="a">10.81043/aperta.99420</subfield>
    <subfield code="i">isVersionOf</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:99421</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="z">md5:3c5c87ff83ce4023db9cb0f6c997bbbb</subfield>
    <subfield code="s">251</subfield>
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/99421/files/bib-598a4231-d85d-4f86-baf7-609a1243eda5.txt</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
    <subfield code="a">Creative Commons Attribution</subfield>
  </datafield>
</record>
28
9
görüntülenme
indirilme
Görüntülenme 28
İndirme 9
Veri hacmi 2.3 kB
Tekil görüntülenme 25
Tekil indirme 8

Alıntı yap