Konferans bildirisi Açık Erişim

New Effective Coaxial Twin-Load Microcalorimeter system

Abdo, Yaser S. E.; Celep, Murat


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/98967</identifier>
  <creators>
    <creator>
      <creatorName>Abdo, Yaser S. E.</creatorName>
      <givenName>Yaser S. E.</givenName>
      <familyName>Abdo</familyName>
      <affiliation>Natl Inst Stand NIS, Giza, Egypt</affiliation>
    </creator>
    <creator>
      <creatorName>Celep, Murat</creatorName>
      <givenName>Murat</givenName>
      <familyName>Celep</familyName>
      <affiliation>TUBITAK Ulusal Metrol Enstitusu, PK 54, TR-41470 Gebze, Turkey</affiliation>
    </creator>
  </creators>
  <titles>
    <title>New Effective Coaxial Twin-Load Microcalorimeter System</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2016</publicationYear>
  <dates>
    <date dateType="Issued">2016-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Conference paper</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/98967</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.81043/aperta.98966</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.81043/aperta.98967</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">This paper describes a new coaxial twin-load microcalorimeter, which was designed and fabricated to be installed at the national metrology institute of Egypt (NIS). Each component of the microcalorimeter measurement setup was measured and characterized separately to ensure its performance. The effective efficiency of a type-N thermistor mount at different frequency points was measured using the designed microcalorimeter setup. A comparison between these measured values and the corresponding effective efficiency measured by the microcalorimeter setup of the national metrology institute of Turkey (TBITAK UME) was done to validate the accuracy of the new setup.</description>
  </descriptions>
</resource>
22
9
görüntülenme
indirilme
Görüntülenme 22
İndirme 9
Veri hacmi 1.4 kB
Tekil görüntülenme 22
Tekil indirme 9

Alıntı yap