Dergi makalesi Açık Erişim
Bilgic, E.
<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
<leader>00000nam##2200000uu#4500</leader>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="p">user-tubitak-adresli-yayinlar</subfield>
<subfield code="o">oai:zenodo.org:98195</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Calibration of shock and vibration transducers is performed by using the methods described in ISO 16063-13 and 16063-22 standards, at primary and secondary levels respectively. At secondary level, the devices, generating mechanical shock, are pendulum shock calibrator, dropball shock calibrator, pneumatically operated piston shock calibrator and Hopkinson bar shock calibrator. The main parameters and requirements of the shock calibrator devices, named here, are also given in ISO 16063-22 standard. Pulse width and pulse amplitude are the important parameters in calibration of the shock and vibration transducers. Pulse width and shape depend on the material properties. In this paper the determination of pulse width and pulse amplitude characteristics of materials used in pendulum type shock calibration device, designed in TUBITAK UME, is presented.</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">publication</subfield>
<subfield code="b">article</subfield>
</datafield>
<datafield tag="540" ind1=" " ind2=" ">
<subfield code="a">Creative Commons Attribution</subfield>
<subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Bilgic, E.</subfield>
<subfield code="u">TUBITAK Ulusal Metrol Enstitusu UME, Gebze, Turkey</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="z">md5:a6efdb315854bfd0fd6764b72f14a51b</subfield>
<subfield code="s">506576</subfield>
<subfield code="u">https://aperta.ulakbim.gov.trrecord/98195/files/10-12693-aphyspola-132-857.pdf</subfield>
</datafield>
<controlfield tag="005">20210316135432.0</controlfield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2017-01-01</subfield>
</datafield>
<datafield tag="024" ind1=" " ind2=" ">
<subfield code="a">10.12693/APhysPolA.132.857</subfield>
<subfield code="2">doi</subfield>
</datafield>
<datafield tag="542" ind1=" " ind2=" ">
<subfield code="l">open</subfield>
</datafield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">Determination of Pulse Width and Pulse Amplitude Characteristics of Materials Used in Pendulum Type Shock Calibration Device</subfield>
</datafield>
<datafield tag="909" ind1="C" ind2="4">
<subfield code="v">132</subfield>
<subfield code="p">ACTA PHYSICA POLONICA A</subfield>
<subfield code="c">857-860</subfield>
<subfield code="n">3</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="7">
<subfield code="a">cc-by</subfield>
<subfield code="2">opendefinition.org</subfield>
</datafield>
<controlfield tag="001">98195</controlfield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-tubitak-adresli-yayinlar</subfield>
</datafield>
</record>
| Görüntülenme | 62 |
| İndirme | 49 |
| Veri hacmi | 24.8 MB |
| Tekil görüntülenme | 58 |
| Tekil indirme | 46 |