Dergi makalesi Açık Erişim

Comparison of Free Space Measurement Using a Vector Network Analyzer and Low-Cost-Type THz-TDS Measurement Methods Between 75 and 325 GHz

Ozturk, Turgut; Morikawa, Osamu; Unal, Ilhami; Uluer, Ihsan


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/98075</identifier>
  <creators>
    <creator>
      <creatorName>Ozturk, Turgut</creatorName>
      <givenName>Turgut</givenName>
      <familyName>Ozturk</familyName>
      <affiliation>Karabuk Univ, Dept Elect Elect Engn, Karabuk, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Morikawa, Osamu</creatorName>
      <givenName>Osamu</givenName>
      <familyName>Morikawa</familyName>
      <affiliation>Japan Coast Guard Acad, Chair Liberal Arts, Kure, Hirosima, Japan</affiliation>
    </creator>
    <creator>
      <creatorName>Unal, Ilhami</creatorName>
      <givenName>Ilhami</givenName>
      <familyName>Unal</familyName>
      <affiliation>TUBITAK MRC, Millimeter Wave &amp; Terahertz Technol Res Labs MILT, Kocaeli, Turkey</affiliation>
    </creator>
    <creator>
      <creatorName>Uluer, Ihsan</creatorName>
      <givenName>Ihsan</givenName>
      <familyName>Uluer</familyName>
      <affiliation>Karabuk Univ, Dept Elect Elect Engn, Karabuk, Turkey</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Comparison Of Free Space Measurement Using A Vector Network Analyzer And Low-Cost-Type Thz-Tds Measurement Methods Between 75 And 325 Ghz</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2017</publicationYear>
  <dates>
    <date dateType="Issued">2017-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/98075</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.1007/s10762-017-0410-1</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">Specifications of two measurement systems, free space measurement using a vector network analyzer and low-cost-type terahertz time-domain spectroscopy using a multimode laser diode, have been compared in the frequency region of millimeter/sub-THz waves. In the comparison, accuracy, cost, measurement time, calculation time, etc. were considered. Four samples (Rexolite, RO3003, Ultralam 3850HT-design, and L1000HF) were selected for the comparison of the specifications of the two methods. The acquired data was used to compute the complex permittivity of measured materials. The extracted results by free space measurement agreed well to the ones obtained by low-cost-type terahertz time-domain spectroscopy. This result proves free space measurement that can be assessed as a new method of material characterization in the sub-THz region successfully worked. Furthermore, free space measurement was proved to be suitable for a measurement in a narrow frequency range. On the other hand, low-cost-type terahertz time-domain spectroscopy has features not only low cost but also measurement capability in wide frequency range.</description>
  </descriptions>
</resource>
21
10
görüntülenme
indirilme
Görüntülenme 21
İndirme 10
Veri hacmi 2.6 kB
Tekil görüntülenme 20
Tekil indirme 10

Alıntı yap