Konferans bildirisi Açık Erişim

Imaging of buried objects by microwave tomography method in conditions of low reflection on surface medium

Vertiy, AA; Gavrilov, S; Aksoy, S


MARC21 XML

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Gavrilov, S</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="a">Aksoy, S</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="a">Creative Commons Attribution</subfield>
    <subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="i">isVersionOf</subfield>
    <subfield code="a">10.81043/aperta.96782</subfield>
    <subfield code="n">doi</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.81043/aperta.96783</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Imaging of buried objects by microwave tomography method in conditions of low reflection on surface medium</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Vertiy, AA</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:zenodo.org:96783</subfield>
    <subfield code="p">user-tubitak-adresli-yayinlar</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="2">opendefinition.org</subfield>
    <subfield code="a">cc-by</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2000-01-01</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">https://aperta.ulakbim.gov.trrecord/96783/files/bib-4a7afdd0-6564-468f-ba47-ca821ee758eb.txt</subfield>
    <subfield code="z">md5:ea46a0dd4b00cd7e1692444df9fa45a9</subfield>
    <subfield code="s">242</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <controlfield tag="005">20210316133444.0</controlfield>
  <controlfield tag="001">96783</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">conferencepaper</subfield>
  </datafield>
  <datafield tag="711" ind1=" " ind2=" ">
    <subfield code="a">2000 2ND INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">One of the most important problems for imaging of buried objects by microwave tomography method is to reflection from surface. Experiments show that the level of surface reflection is very big. Because of this big reflection from surface, it is very hard to get images from weakly scattered objects like mine etc, if they are buried close to surface. This paper shows that if incident wave is arranged at Brewster angle, surface reflection is decreased and the imaging by microwave tomography method of buried weakly scattered objects like mine etc, are better than at non Brewster angle[1].</subfield>
  </datafield>
</record>
34
8
görüntülenme
indirilme
Görüntülenme 34
İndirme 8
Veri hacmi 1.9 kB
Tekil görüntülenme 33
Tekil indirme 8

Alıntı yap