Konferans bildirisi Açık Erişim
Ermis, M; Cakir, Z; Cadirci, I; Zenginobuz, G; Tezcan, H
{ "conceptdoi": "10.81043/aperta.94922", "conceptrecid": "94922", "created": "2021-03-16T13:08:47.159792+00:00", "doi": "10.81043/aperta.94923", "files": [ { "bucket": "143a4eb8-37ad-4af6-ba52-a0cf1486f6d7", "checksum": "md5:96c2d8328f292925d25b269c4e3c3fcf", "key": "bib-d951080d-90da-495f-8c87-2a9aa3db51b6.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/143a4eb8-37ad-4af6-ba52-a0cf1486f6d7/bib-d951080d-90da-495f-8c87-2a9aa3db51b6.txt" }, "size": 286, "type": "txt" } ], "id": 94923, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.94923.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/143a4eb8-37ad-4af6-ba52-a0cf1486f6d7", "conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.81043/aperta.94922.svg", "conceptdoi": "https://doi.org/10.81043/aperta.94922", "doi": "https://doi.org/10.81043/aperta.94923", "html": "https://aperta.ulakbim.gov.tr/record/94923", "latest": "https://aperta.ulakbim.gov.tr/api/records/94923", "latest_html": "https://aperta.ulakbim.gov.tr/record/94923" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-adresli-yayinlar" } ], "creators": [ { "name": "Ermis, M" }, { "name": "Cakir, Z" }, { "name": "Cadirci, I" }, { "name": "Zenginobuz, G" }, { "name": "Tezcan, H" } ], "description": "Self-excitation of induction motors compensated by permanently-connected capacitors is investigated in this paper. Theoretical analyses of self-excitation phenomenon are carried out by using some simplified equivalent circuits, and a hybrid mathematical model in ABC/dq axes, respectively in steady-state, and transient-state. An unusual operating condition about water pumping stations is reported, in which water within the pipeline may drive the motor in the reverse direction at speeds higher than synchronous, when a supply interruption coincides with a check valve failure. In order to prevent the motor from dangerous overvoltages due to self-excitation, it is recommended to connect a simple static protection circuit consisting of a resistor in series with a thyristor switch between any two lines of the motor. Critical resistance boundaries which will lead to loss of excitation, and demagnetisation of the rotor core are determined separately as a function of operating speed. A suitable resistance value chosen in the Safe Design Area constitutes a reliable protection mechanism against self-excitation.", "doi": "10.81043/aperta.94923", "has_grant": false, "license": { "id": "cc-by" }, "meeting": { "title": "IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5" }, "publication_date": "2000-01-01", "related_identifiers": [ { "identifier": "10.81043/aperta.94922", "relation": "isVersionOf", "scheme": "doi" } ], "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "94923" }, "parent": { "pid_type": "recid", "pid_value": "94922" } } ] }, "resource_type": { "subtype": "conferencepaper", "title": "Konferans bildirisi", "type": "publication" }, "title": "Self excitation of induction motors compensated by permanently connected capacitors and recommendations for IEEE Std 141-1993" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 7.0, "unique_downloads": 7.0, "unique_views": 28.0, "version_downloads": 7.0, "version_unique_downloads": 7.0, "version_unique_views": 28.0, "version_views": 30.0, "version_volume": 2002.0, "views": 30.0, "volume": 2002.0 }, "updated": "2021-03-16T13:08:47.201259+00:00" }
Görüntülenme | 30 |
İndirme | 7 |
Veri hacmi | 2.0 kB |
Tekil görüntülenme | 28 |
Tekil indirme | 7 |