Konferans bildirisi Açık Erişim

Realization and dissemination of linear acceleration unit at UME

Sadikoglu, E; Bilgic, E; Karaboce, B


DataCite XML

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/93577</identifier>
  <creators>
    <creator>
      <creatorName>Sadikoglu, E</creatorName>
      <givenName>E</givenName>
      <familyName>Sadikoglu</familyName>
    </creator>
    <creator>
      <creatorName>Bilgic, E</creatorName>
      <givenName>E</givenName>
      <familyName>Bilgic</familyName>
    </creator>
    <creator>
      <creatorName>Karaboce, B</creatorName>
      <givenName>B</givenName>
      <familyName>Karaboce</familyName>
    </creator>
  </creators>
  <titles>
    <title>Realization And Dissemination Of Linear Acceleration Unit At Ume</title>
  </titles>
  <publisher>Aperta</publisher>
  <publicationYear>2002</publicationYear>
  <dates>
    <date dateType="Issued">2002-01-01</date>
  </dates>
  <resourceType resourceTypeGeneral="Text">Conference paper</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/93577</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.81043/aperta.93576</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.81043/aperta.93577</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">At Turkish National Metrology Institute (UME), linear acceleration unit has been realized based on laser interferometry with different signal processing techniques. Absolute calibrations of reference accelerometers are performed by using fringe-counting and minimum point method in the frequency range from 20 to 10000 Hz. Dissemination of the linear acceleration unit to the secondary levels is carried out through a comparison calibration of vibration pick-ups by "back-to-back" method. Traceability chain for calibrations of the vibration calibrations and measurements performed at UME has been described in this paper.</description>
  </descriptions>
</resource>
36
5
görüntülenme
indirilme
Görüntülenme 36
İndirme 5
Veri hacmi 1.1 kB
Tekil görüntülenme 35
Tekil indirme 5

Alıntı yap