Konferans bildirisi Açık Erişim
Sadikoglu, E; Bilgic, E; Karaboce, B
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="URL">https://aperta.ulakbim.gov.tr/record/93577</identifier> <creators> <creator> <creatorName>Sadikoglu, E</creatorName> <givenName>E</givenName> <familyName>Sadikoglu</familyName> </creator> <creator> <creatorName>Bilgic, E</creatorName> <givenName>E</givenName> <familyName>Bilgic</familyName> </creator> <creator> <creatorName>Karaboce, B</creatorName> <givenName>B</givenName> <familyName>Karaboce</familyName> </creator> </creators> <titles> <title>Realization And Dissemination Of Linear Acceleration Unit At Ume</title> </titles> <publisher>Aperta</publisher> <publicationYear>2002</publicationYear> <dates> <date dateType="Issued">2002-01-01</date> </dates> <resourceType resourceTypeGeneral="Text">Conference paper</resourceType> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://aperta.ulakbim.gov.tr/record/93577</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.81043/aperta.93576</relatedIdentifier> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo">10.81043/aperta.93577</relatedIdentifier> </relatedIdentifiers> <rightsList> <rights rightsURI="http://www.opendefinition.org/licenses/cc-by">Creative Commons Attribution</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract">At Turkish National Metrology Institute (UME), linear acceleration unit has been realized based on laser interferometry with different signal processing techniques. Absolute calibrations of reference accelerometers are performed by using fringe-counting and minimum point method in the frequency range from 20 to 10000 Hz. Dissemination of the linear acceleration unit to the secondary levels is carried out through a comparison calibration of vibration pick-ups by "back-to-back" method. Traceability chain for calibrations of the vibration calibrations and measurements performed at UME has been described in this paper.</description> </descriptions> </resource>
Görüntülenme | 36 |
İndirme | 5 |
Veri hacmi | 1.1 kB |
Tekil görüntülenme | 35 |
Tekil indirme | 5 |