Konferans bildirisi Açık Erişim
Kanatoglu, Naylan; Orhan, Recep; Arifovic, Mehedin
<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
<leader>00000nam##2200000uu#4500</leader>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="p">user-tubitak-adresli-yayinlar</subfield>
<subfield code="o">oai:zenodo.org:93425</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Programmable Josephson Voltage Standard (PJVS) recently established in TUBITAK UME, is used to investigate the linearity of the high precision digital voltmeters (DVM). The new system with fast settling and stable output voltages is an efficient tool to test DVM linearity from 0 to +/- 10V with an uncertainty better than 0.1 mu V/V.</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">publication</subfield>
<subfield code="b">conferencepaper</subfield>
</datafield>
<datafield tag="711" ind1=" " ind2=" ">
<subfield code="a">2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018)</subfield>
</datafield>
<datafield tag="540" ind1=" " ind2=" ">
<subfield code="a">Creative Commons Attribution</subfield>
<subfield code="u">http://www.opendefinition.org/licenses/cc-by</subfield>
</datafield>
<datafield tag="773" ind1=" " ind2=" ">
<subfield code="i">isVersionOf</subfield>
<subfield code="a">10.81043/aperta.93424</subfield>
<subfield code="n">doi</subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Kanatoglu, Naylan</subfield>
<subfield code="u">TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="z">md5:79018ce95a1b874ce448ce22b3bc3c1e</subfield>
<subfield code="s">218</subfield>
<subfield code="u">https://aperta.ulakbim.gov.trrecord/93425/files/bib-2bb52767-b6f4-4db8-a0f3-5a1b951a88c1.txt</subfield>
</datafield>
<controlfield tag="005">20210316124837.0</controlfield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2018-01-01</subfield>
</datafield>
<datafield tag="024" ind1=" " ind2=" ">
<subfield code="a">10.81043/aperta.93425</subfield>
<subfield code="2">doi</subfield>
</datafield>
<datafield tag="542" ind1=" " ind2=" ">
<subfield code="l">open</subfield>
</datafield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">Linearity Testing of High Precision Digital Voltmeters with Programmable Josephson Voltage Standard</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="7">
<subfield code="a">cc-by</subfield>
<subfield code="2">opendefinition.org</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Orhan, Recep</subfield>
<subfield code="u">TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Arifovic, Mehedin</subfield>
<subfield code="u">TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey</subfield>
</datafield>
<controlfield tag="001">93425</controlfield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-tubitak-adresli-yayinlar</subfield>
</datafield>
</record>
| Görüntülenme | 30 |
| İndirme | 8 |
| Veri hacmi | 1.7 kB |
| Tekil görüntülenme | 30 |
| Tekil indirme | 8 |