Konferans bildirisi Açık Erişim
Yilmaz, Ozgur; Selimoglu, Ozgur; Turk, Fethi
{ "conceptrecid": "91470", "created": "2021-03-16T12:21:45.927214+00:00", "doi": "10.1117/12.2024506", "files": [ { "bucket": "8a8c66cc-89e7-4ddc-9165-f16a896f149e", "checksum": "md5:a102d62eaf0bd089042facc91358fdb3", "key": "bib-2c9d4aa5-9235-49ba-8b8d-7a615d5d0635.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/8a8c66cc-89e7-4ddc-9165-f16a896f149e/bib-2c9d4aa5-9235-49ba-8b8d-7a615d5d0635.txt" }, "size": 203, "type": "txt" } ], "id": 91471, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1117/12.2024506.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/8a8c66cc-89e7-4ddc-9165-f16a896f149e", "doi": "https://doi.org/10.1117/12.2024506", "html": "https://aperta.ulakbim.gov.tr/record/91471", "latest": "https://aperta.ulakbim.gov.tr/api/records/91471", "latest_html": "https://aperta.ulakbim.gov.tr/record/91471" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-adresli-yayinlar" } ], "creators": [ { "affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey", "name": "Yilmaz, Ozgur" }, { "affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey", "name": "Selimoglu, Ozgur" }, { "affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey", "name": "Turk, Fethi" } ], "description": "Development of an imaging telescope having a large mirror generally requires a sound infrastructure including expensive devices such as collimators and interferometers. In this paper we investigate the development and characterization of a medium size telescope (140 mm aperture) using simple techniques. Alignment was done with a mechanical measurement device. Detector was placed using an image of a ruled outside building. Radiometric calibration was done with open-sky images. And finally MTF was measured using stellar images. We found that MTF of our telescope is greater than %15 all along the detector at 20 lp/mm, which is the Nyquist frequency of 25 mu m pixel size. This shows that alignment and focus adjustments work well enough in the telescope. These simple techniques can be used for the development and characterization of a medium-size and medium-resolution imaging telescopes.", "doi": "10.1117/12.2024506", "has_grant": false, "license": { "id": "cc-by" }, "meeting": { "title": "OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION VII" }, "publication_date": "2013-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "91471" }, "parent": { "pid_type": "recid", "pid_value": "91470" } } ] }, "resource_type": { "subtype": "conferencepaper", "title": "Konferans bildirisi", "type": "publication" }, "title": "Development of a medium size SWIR imaging telescope: integration, calibration and MTF measurement" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 3.0, "unique_downloads": 3.0, "unique_views": 8.0, "version_downloads": 3.0, "version_unique_downloads": 3.0, "version_unique_views": 8.0, "version_views": 8.0, "version_volume": 609.0, "views": 8.0, "volume": 609.0 }, "updated": "2021-03-16T12:21:45.977668+00:00" }
Görüntülenme | 8 |
İndirme | 3 |
Veri hacmi | 609 Bytes |
Tekil görüntülenme | 8 |
Tekil indirme | 3 |