Konferans bildirisi Açık Erişim
Yilmaz, Ozgur; Selimoglu, Ozgur; Turk, Fethi
{
"conceptrecid": "91470",
"created": "2021-03-16T12:21:45.927214+00:00",
"doi": "10.1117/12.2024506",
"files": [
{
"bucket": "8a8c66cc-89e7-4ddc-9165-f16a896f149e",
"checksum": "md5:a102d62eaf0bd089042facc91358fdb3",
"key": "bib-2c9d4aa5-9235-49ba-8b8d-7a615d5d0635.txt",
"links": {
"self": "https://aperta.ulakbim.gov.tr/api/files/8a8c66cc-89e7-4ddc-9165-f16a896f149e/bib-2c9d4aa5-9235-49ba-8b8d-7a615d5d0635.txt"
},
"size": 203,
"type": "txt"
}
],
"id": 91471,
"links": {
"badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1117/12.2024506.svg",
"bucket": "https://aperta.ulakbim.gov.tr/api/files/8a8c66cc-89e7-4ddc-9165-f16a896f149e",
"doi": "https://doi.org/10.1117/12.2024506",
"html": "https://aperta.ulakbim.gov.tr/record/91471",
"latest": "https://aperta.ulakbim.gov.tr/api/records/91471",
"latest_html": "https://aperta.ulakbim.gov.tr/record/91471"
},
"metadata": {
"access_right": "open",
"access_right_category": "success",
"communities": [
{
"id": "tubitak-adresli-yayinlar"
}
],
"creators": [
{
"affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey",
"name": "Yilmaz, Ozgur"
},
{
"affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey",
"name": "Selimoglu, Ozgur"
},
{
"affiliation": "Middle E Tech Univ, Tubitak Uzay Space Technol Res Inst, TR-06531 Ankara, Turkey",
"name": "Turk, Fethi"
}
],
"description": "Development of an imaging telescope having a large mirror generally requires a sound infrastructure including expensive devices such as collimators and interferometers. In this paper we investigate the development and characterization of a medium size telescope (140 mm aperture) using simple techniques. Alignment was done with a mechanical measurement device. Detector was placed using an image of a ruled outside building. Radiometric calibration was done with open-sky images. And finally MTF was measured using stellar images. We found that MTF of our telescope is greater than %15 all along the detector at 20 lp/mm, which is the Nyquist frequency of 25 mu m pixel size. This shows that alignment and focus adjustments work well enough in the telescope. These simple techniques can be used for the development and characterization of a medium-size and medium-resolution imaging telescopes.",
"doi": "10.1117/12.2024506",
"has_grant": false,
"license": {
"id": "cc-by"
},
"meeting": {
"title": "OPTICAL SYSTEM ALIGNMENT, TOLERANCING, AND VERIFICATION VII"
},
"publication_date": "2013-01-01",
"relations": {
"version": [
{
"count": 1,
"index": 0,
"is_last": true,
"last_child": {
"pid_type": "recid",
"pid_value": "91471"
},
"parent": {
"pid_type": "recid",
"pid_value": "91470"
}
}
]
},
"resource_type": {
"subtype": "conferencepaper",
"title": "Konferans bildirisi",
"type": "publication"
},
"title": "Development of a medium size SWIR imaging telescope: integration, calibration and MTF measurement"
},
"owners": [
1
],
"revision": 1,
"stats": {
"downloads": 6.0,
"unique_downloads": 6.0,
"unique_views": 23.0,
"version_downloads": 6.0,
"version_unique_downloads": 6.0,
"version_unique_views": 23.0,
"version_views": 26.0,
"version_volume": 1218.0,
"views": 26.0,
"volume": 1218.0
},
"updated": "2021-03-16T12:21:45.977668+00:00"
}
| Görüntülenme | 26 |
| İndirme | 6 |
| Veri hacmi | 1.2 kB |
| Tekil görüntülenme | 23 |
| Tekil indirme | 6 |