Dergi makalesi Açık Erişim
Cetkin, Erdal
{ "conceptrecid": "81274", "created": "2021-03-16T05:45:23.186166+00:00", "doi": "10.1115/1.4030906", "files": [ { "bucket": "9cb1c98c-ea6d-4b5e-a4a2-126f3587eed5", "checksum": "md5:fcb8257ea68b3026dc5eda63bb3240f7", "key": "bib-77175da5-b2c8-4629-8e40-463168087d34.txt", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/9cb1c98c-ea6d-4b5e-a4a2-126f3587eed5/bib-77175da5-b2c8-4629-8e40-463168087d34.txt" }, "size": 159, "type": "txt" } ], "id": 81275, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.1115/1.4030906.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/9cb1c98c-ea6d-4b5e-a4a2-126f3587eed5", "doi": "https://doi.org/10.1115/1.4030906", "html": "https://aperta.ulakbim.gov.tr/record/81275", "latest": "https://aperta.ulakbim.gov.tr/api/records/81275", "latest_html": "https://aperta.ulakbim.gov.tr/record/81275" }, "metadata": { "access_right": "open", "access_right_category": "success", "communities": [ { "id": "tubitak-destekli-proje-yayinlari" } ], "creators": [ { "name": "Cetkin, Erdal" } ], "description": "In this paper, we show how a heat-generating domain can be cooled with embedded cooling channels and high-conductivity inserts. The volume of cooling channels and high-conductivity inserts is fixed, so is the volume of the heat-generating domain. The maximum temperature in the domain decreases with high-conductivity inserts even though the coolant volume decreases. The locations and the shapes of high-conductivity inserts corresponding to the smallest peak temperatures for different number of inserts are documented, x = 0.6L and D/B -0.11 with two rectangular inserts. We also document how the length scales of the inserts should be changed as the volume fraction of the coolant volume over the high-conductivity material volume varies. The high-conductivity inserts should be placed nonequidistantly in order to provide the smallest peak temperature in the heat-generating domain. In addition, increasing the number of the inserts after a limit increases the peak temperature, i.e., this limit is eight number of inserts for the given conditions and assumptions. This paper shows that the overall thermal conductance of a heat-generating domain can be increased by embedding high-conductivity material in the solid domain (inverted fins) when the domain is cooled with forced convection, and the summation of high-conductivity material volume and coolant volume is fixed.", "doi": "10.1115/1.4030906", "has_grant": false, "journal": { "issue": "11", "title": "JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME", "volume": "137" }, "license": { "id": "cc-by" }, "publication_date": "2015-01-01", "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "81275" }, "parent": { "pid_type": "recid", "pid_value": "81274" } } ] }, "resource_type": { "subtype": "article", "title": "Dergi makalesi", "type": "publication" }, "title": "Constructal Vascular Structures With High-Conductivity Inserts for Self-Cooling" }, "owners": [ 1 ], "revision": 1, "stats": { "downloads": 7.0, "unique_downloads": 7.0, "unique_views": 46.0, "version_downloads": 7.0, "version_unique_downloads": 7.0, "version_unique_views": 46.0, "version_views": 51.0, "version_volume": 1113.0, "views": 51.0, "volume": 1113.0 }, "updated": "2021-03-16T05:45:23.229367+00:00" }
Görüntülenme | 51 |
İndirme | 7 |
Veri hacmi | 1.1 kB |
Tekil görüntülenme | 46 |
Tekil indirme | 7 |